8051 CROSS ASSEMBLER
|
||
|
||
|
||
USER'S MANUAL
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
MetaLink Corporation
|
||
Chandler, Arizona
|
||
|
||
|
||
|
||
|
||
|
||
|
||
MetaLink Corporation
|
||
P.O. BOX 1329
|
||
Chandler, Arizona 85244-1329
|
||
(602) 926-0797
|
||
TELEX: 4998050 MTLNK
|
||
FAX: (602) 926-1198
|
||
|
||
|
||
|
||
|
||
PURCHASE TERMS AND CONDITIONS
|
||
|
||
|
||
Since MetaLink Corporation does business and is located solely in
|
||
the State of Arizona, such orders or agreements and the rights of
|
||
the parties hereunder shall be governed by the laws of the State
|
||
of Arizona.
|
||
|
||
|
||
PAYMENTS TERMS:
|
||
|
||
Unless otherwise agreed upon, the TOTAL UNPAID BALANCE is due and
|
||
payable 30 days following the invoice date.
|
||
|
||
|
||
LIMITED WARRANTY: METALINK MAKES NO WARRANTIES OTHER THAN THOSE
|
||
CONTAINED HEREIN AND METALINK EXPRESSLY DISCLAIMS ANY AND ALL
|
||
IMPLIED WARRANTIES, INCLUDING ANY WARRANTY OF FITNESS FOR A
|
||
PARTICULAR PURPOSE OR OF MERCHANTABILITY.
|
||
|
||
|
||
The foregoing limited warranty shall not apply unless Buyer has
|
||
paid for in full the MetaLink products. Updates to the MetaLink
|
||
Assembler User's Manual and MetaLink Assembler software are
|
||
available free to Registered Buyer upon request for a one (1) year
|
||
period from the invoice date.
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
NOTICE
|
||
|
||
MetaLink Corp. reserves the right to make improvements in the
|
||
software product described in this manual as well as the manual
|
||
itself at any time and without notice.
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
DISCLAIMER OF ALL WARRANTIES AND LIABILITY
|
||
|
||
METALINK CORP. MAKES NO WARRANTIES, EITHER EXPRESSED OR IMPLIED,
|
||
WITH RESPECT TO THIS MANUAL OR WITH RESPECT TO THE SOFTWARE
|
||
DESCRIBED IN THIS MANUAL, ITS QUALITY, PERFORMANCE, MERCHANTABILITY,
|
||
OR FITNESS FOR ANY PARTICULAR PURPOSE. METALINK CORP. SOFTWARE
|
||
IS SOLD OR LICENSED "AS IS". IN NO EVENT SHALL METALINK CORP. BE
|
||
LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING FROM ANY
|
||
DEFECT IN THE SOFTWARE.
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
Copyright (c) 1984, 1985, 1986, 1987, 1988, 1989 by MetaLink Corp.
|
||
|
||
All rights are reserved. This manual may not, in whole or part,
|
||
be copied, photocopied, reproduced, translated, or reduced to any
|
||
electronic medium or machine readable form without the prior
|
||
agreement and written permission of MetaLink Corp.
|
||
|
||
|
||
|
||
|
||
|
||
MS-DOS is a trademark of Microsoft, Inc.
|
||
|
||
IBMR is a registered trademark of IBM Corp.
|
||
|
||
IntelR is a registered trademark of Intel Corp.
|
||
|
||
MetaLink is a trademark of MetaLink Corp.
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
T A B L E O F C O N T E N T S
|
||
|
||
1. 8051 OVERVIEW............................................1-1
|
||
1.1. Introduction........................................1-1
|
||
1.2. 8051 Architecture...................................1-2
|
||
1.3. Summary of the 8051 Family of Components............1-4
|
||
1.4. References..........................................1-5
|
||
|
||
2. 8051 CROSS ASSEMBLER OVERVIEW............................2-1
|
||
2.1. Introduction........................................2-1
|
||
2.2. Symbols.............................................2-1
|
||
2.3. Labels..............................................2-2
|
||
2.4. Assembler Controls..................................2-3
|
||
2.5. Assembler Directives................................2-3
|
||
2.6. 8051 Instruction Mnemonics..........................2-4
|
||
2.7. Bit Addressing......................................2-6
|
||
2.8. ASCII Literals......................................2-6
|
||
2.9. Comments............................................2-6
|
||
2.10. The Location Counter...............................2-7
|
||
2.11. Syntax Summary.....................................2-7
|
||
2.12. Numbers and Operators..............................2-7
|
||
2.13. Source File Listing...............................2-10
|
||
2.14. Object File.......................................2-11
|
||
|
||
3. RUNNING THE 8051 CROSS ASSEMBLER.........................3-1
|
||
3.1. Cross Assembler Files...............................3-1
|
||
3.2. Minimum System Requirements.........................3-1
|
||
3.3. Running the Cross Assembler.........................3-1
|
||
3.4. Example Running the Cross Assembler.................3-3
|
||
3.5. DOS Hints and Suggestions...........................3-3
|
||
3.6. References..........................................3-4
|
||
|
||
4. 8051 INSTRUCTION SET.....................................4-1
|
||
4.1. Notation............................................4-1
|
||
4.2. 8051 Instruction Set Summary........................4-4
|
||
4.3. Notes..............................................4-14
|
||
4.4. References.........................................4-14
|
||
|
||
5. 8051 CROSS ASSEMBLER DIRECTIVES..........................5-1
|
||
5.1. Introduction........................................5-1
|
||
5.2. Symbol Definition Directives........................5-1
|
||
5.3. Segment Selection Directives........................5-4
|
||
5.4. Memory Reservation and Storage Directives...........5-5
|
||
5.5. Miscellaneous Directives............................5-7
|
||
5.6. Conditional Assembly Directives.....................5-8
|
||
|
||
6. 8051 CROSS ASSEMBLER CONTROLS............................6-1
|
||
6.1. Introduction........................................6-1
|
||
6.2. Assembler Control Descriptions......................6-1
|
||
|
||
|
||
|
||
|
||
|
||
7. 8051 CROSS ASSEMBLER MACRO PROCESSOR.....................7-1
|
||
7.1. Introduction........................................7-1
|
||
7.2. Macro Definition....................................7-1
|
||
7.3. Special Macro Operators.............................7-4
|
||
7.4. Using Macros........................................7-4
|
||
7.4.1. NESTING MACROS...............................7-4
|
||
7.4.2. LABELS IN MACROS.............................7-6
|
||
|
||
8. 8051 CROSS ASSEMBLER ERROR CODES.........................8-1
|
||
8.1. Introduction........................................8-1
|
||
8.2. Explanation of Error Messages.......................8-2
|
||
|
||
|
||
|
||
Appendices
|
||
|
||
A. SAMPLE PROGRAM AND LISTING...............................A-1
|
||
A.1. Source File.........................................A-1
|
||
A.2. Source File Listing.................................A-4
|
||
|
||
B. PRE-DEFINED BYTE AND BIT ADDRESSES.......................B-1
|
||
B.1. Pre-defined Byte Addresses..........................B-1
|
||
B.2. Pre-defined Bit Addresses..........................B-11
|
||
|
||
C. RESERVED SYMBOLS.........................................C-1
|
||
|
||
D. CROSS ASSEMBLER CHARACTER SET............................D-1
|
||
|
||
|
||
|
||
|
||
|
||
CHAPTER 1
|
||
|
||
|
||
8051 OVERVIEW
|
||
|
||
1.1. Introduction
|
||
|
||
For new users of MetaLink's ASM51 Cross Assembler, please take a
|
||
moment to fill out and return postage-prepaid User Registration
|
||
Card. This card will be found with the system diskette in the
|
||
vinyl jacket at the front of this manual. MetaLink will use this
|
||
information to send out, free of charge, any software updates
|
||
occurring during the warranty period. Respondents will also be
|
||
notified of any new products or product enhancements.
|
||
|
||
The 8051 series of microcontrollers are highly integrated single
|
||
chip microcomputers with an 8-bit CPU, memory, interrupt
|
||
controller, timers, serial I/O and digital I/O on a single piece
|
||
of silicon. The current members of the 8051 family of components
|
||
include:
|
||
|
||
80C152JA/JB/JC/JD, 83C152JA/JC, 80C157
|
||
80C154, 83C154, 85C154
|
||
8044, 8344, 8744
|
||
80C451, 83C451, 87C451
|
||
80C452, 83C452, 87C452
|
||
8051, 8031, 8751, 80C51, 80C31, 87C51
|
||
80512, 80532
|
||
80515, 80535, 80C535, 80C515
|
||
80C517, 80C537
|
||
80C51FA, 83C51FA, 87C51FA, 83C51FB, 87C51FB, 83C51FC, 87C51FC
|
||
8052, 8032, 8752
|
||
80C321, 80C521, 87C521, 80C541, 87C541
|
||
8053, 9761, 8753
|
||
80C552, 83C552, 87C552
|
||
80C652, 83C652, 87C652
|
||
83C654, 87C654
|
||
83C751, 87C751
|
||
83C752, 87C752
|
||
80C851, 83C851
|
||
|
||
All members of the 8051 series of microcontrollers share a common
|
||
architecture. They all have the same instruction set, addressing
|
||
modes, addressing range and memory spaces. The primary
|
||
differences between different 8051 based products are the amount
|
||
of memory on chip, the amount and types of I/O and peripheral
|
||
functions, and the component's technology (see Table 1-1).
|
||
|
||
In the brief summary of the 8051 architecture that follows, the
|
||
term 8051 is used to mean collectively all available members of
|
||
the 8051 family. Please refer to reference (1) for a complete
|
||
description of the 8051 architecture and the specifications for
|
||
all the currently available 8051 based products.
|
||
|
||
|
||
|
||
1-1
|
||
|
||
|
||
|
||
|
||
1.2. 8051 Architecture
|
||
|
||
The 8051 is an 8-bit machine. Its memory is organized in bytes
|
||
and practically all its instruction deal with byte quantities.
|
||
It uses an Accumulator as the primary register for instruction
|
||
results. Other operands can be accessed using one of the four
|
||
different addressing modes available: register implicit, direct,
|
||
indirect or immediate. Operands reside in one of the five memory
|
||
spaces of the 8051.
|
||
|
||
The five memory spaces of the 8051 are: Program Memory, External
|
||
Data Memory, Internal Data Memory, Special Function Registers and
|
||
Bit Memory.
|
||
|
||
The Program Memory space contains all the instructions, immediate
|
||
data and constant tables and strings. It is principally
|
||
addressed by the 16-bit Program Counter (PC), but it can also be
|
||
accessed by a few instructions using the 16-bit Data Pointer
|
||
(DPTR). The maximum size of the Program Memory space is 64K
|
||
bytes. Several 8051 family members integrate on-chip some amount
|
||
of either masked programmed ROM or EPROM as part of this memory
|
||
space (refer to Table 1-1).
|
||
|
||
The External Data Memory space contains all the variables,
|
||
buffers and data structures that can't fit on-chip. It is
|
||
principally addressed by the 16-bit Data Pointer (DPTR), although
|
||
the first two general purpose register (R0,R1) of the currently
|
||
selected register bank can access a 256-byte bank of External
|
||
Data Memory. The maximum size of the External Data Memory space
|
||
is 64Kbytes. External data memory can only be accessed using
|
||
the indirect addressing mode with the DPTR, R0 or R1.
|
||
|
||
The Internal Data Memory space is functionally the most important
|
||
data memory space. In it resides up to four banks of general
|
||
purpose registers, the program stack, 128 bits of the 256-bit
|
||
memory, and all the variables and data structures that are
|
||
operated on directly by the program. The maximum size of the
|
||
Internal Data Memory space is 256-bytes. However, different
|
||
8051 family members integrate different amounts of this memory
|
||
space on chip (see Amnt of RAM in Table 1-1). The register
|
||
implicit, indirect and direct addressing modes can be used in
|
||
different parts of the Internal Data Memory space.
|
||
|
||
The Special Function Register space contains all the on-chip
|
||
peripheral I/O registers as well as particular registers that
|
||
need program access. These registers include the Stack Pointer,
|
||
the PSW and the Accumulator. The maximum number of Special
|
||
Function Registers (SFRs) is 128, though the actual number on a
|
||
particular 8051 family member depends on the number and type of
|
||
peripheral functions integrated on-chip (see Table 1-1). The
|
||
SFRs all have addresses greater than 127 and overlap the address
|
||
space of the upper 128 bytes of the Internal Data Memory space.
|
||
The two memory spaces are differentiated by addressing mode. The
|
||
SFRs can only be accessed using the Direct addressing mode while
|
||
the upper 128 bytes of the Internal Data Memory (if integrated
|
||
on-chip) can only be accessed using the Indirect addressing mode.
|
||
|
||
|
||
1-2
|
||
|
||
|
||
|
||
|
||
The Bit Memory space is used for storing bit variables and flags.
|
||
There are specific instructions in the 8051 that operate only in
|
||
the Bit Memory space. The maximum size of the Bit Memory space
|
||
is 256-bits. 128 of the bits overlap with 16-bytes of the
|
||
Internal Data Memory space and 128 of the bits overlap with 16
|
||
Special Function Registers. Bits can only be accessed using the
|
||
bit instructions and the Direct addressing mode.
|
||
|
||
The 8051 has a fairly complete set of arithmetic and logical
|
||
instructions. It includes an 8X8 multiply and an 8/8 divide.
|
||
The 8051 is particularly good at processing bits (sometimes
|
||
called Boolean Processing). Using the Carry Flag in the PSW as a
|
||
single bit accumulator, the 8051 can move and do logical
|
||
operations between the Bit Memory space and the Carry Flag. Bits
|
||
in the Bit Memory space can also be used as general purpose flags
|
||
for the test bit and jump instructions.
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
1-3
|
||
|
||
|
||
|
||
|
||
Except for the MOVE instruction, the 8051 instructions can only
|
||
operate on either the Internal Data Memory space or the Special
|
||
Function Registers. The MOVE instruction operates in all memory
|
||
spaces, including the External Memory space and Program Memory
|
||
space.
|
||
|
||
Program control instructions include the usual unconditional
|
||
calls and jumps as well as conditional relative jumps based on
|
||
the Carry Flag, the Accumulator's zero state, and the state of
|
||
any bit in the Bit Memory space. Also available is a Compare and
|
||
Jump if Not Equal instruction and a Decrement Counter and Jump if
|
||
Not Zero loop instruction. See Chapter 4 for a description of
|
||
the complete 8051 instruction set.
|
||
|
||
1.3. Summary of the 8051 Family of Components
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
1-4
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
Table 1-1: 8051 Family of Components
|
||
|
||
|
||
1.4. References
|
||
|
||
1. Intel Corp., 8-Bit Embedded Controllers, 1990.
|
||
2. Siemens Corp., Microcontroller Component 80515, 1985.
|
||
3. AMD Corp., Eight-Bit 80C51 Embedded Processors, 1990.
|
||
4. Signetics Corp., Microcontroller Users' Guide, 1989.
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
1-5
|
||
|
||
|
||
|
||
|
||
|
||
|
||
CHAPTER 2
|
||
|
||
|
||
8051 CROSS ASSEMBLER OVERVIEW
|
||
|
||
|
||
2.1. Introduction
|
||
|
||
The 8051 Cross Assembler takes an assembly language source file
|
||
created with a text editor and translates it into a machine
|
||
language object file. This translation process is done in two
|
||
passes over the source file. During the first pass, the Cross
|
||
Assembler builds a symbol table from the symbols and labels used
|
||
in the source file. It's during the second pass that the Cross
|
||
Assembler actually translates the source file into the machine
|
||
language object file. It is also during the second pass that the
|
||
listing is generated.
|
||
|
||
The following is a discussion of the syntax required by the Cross
|
||
Assembler to generate error free assemblies.
|
||
|
||
|
||
2.2. Symbols
|
||
|
||
Symbols are alphanumeric representations of numeric constants,
|
||
addresses, macros, etc. The legal character set for symbols is
|
||
the set of letters, both upper and lower case (A..Z,a..z), the
|
||
set of decimal numbers (0..9) and the special characters,
|
||
question mark (?) and underscore (_). To ensure that the Cross
|
||
Assembler can distinguish between a symbol and a number, all
|
||
symbols must start with either a letter or special character (?
|
||
or _). The following are examples of legal symbols:
|
||
|
||
PI
|
||
Serial_Port_Buffer
|
||
LOC_4096
|
||
?_?_?
|
||
|
||
In using a symbol, the Cross Assembler converts all letters to
|
||
upper case. As a result, the Cross Assembler makes no distinction
|
||
between upper and lower case letters. For example, the following
|
||
two symbols would be seen as the same symbol by the Cross
|
||
Assembler:
|
||
|
||
Serial_Port_Buffer
|
||
SERIAL_PORT_BUFFER
|
||
|
||
Symbols can be defined only once. Symbols can be up to 255
|
||
characters in length, though only the first 32 are significant.
|
||
Therefore, for symbols to be unique, they must have a unique
|
||
character pattern within the first 32 characters. In the
|
||
following example, the first two symbols would be seen by the
|
||
Cross Assembler as duplicate symbols, while the third and fourth
|
||
|
||
|
||
2-1
|
||
|
||
|
||
|
||
|
||
symbols are unique.
|
||
|
||
BEGINNING_ADDRESS_OF_CONSTANT_TABLE_1
|
||
BEGINNING_ADDRESS_OF_CONSTANT_TABLE_2
|
||
|
||
CONSTANT_TABLE_1_BEGINNING_ADDRESS
|
||
CONSTANT_TABLE_2_BEGINNING_ADDRESS
|
||
|
||
There are certain symbols that are reserved and can't be defined
|
||
by the user. These reserved symbols are listed in Appendix C and
|
||
include the assembler directives, the 8051 instruction mnemonics,
|
||
implicit operand symbols, and the following assembly time
|
||
operators that have alphanumeric symbols: EQ, NE, GT, GE, LT, LE,
|
||
HIGH, LOW, MOD, SHR, SHL, NOT,
|
||
AND, OR and XOR.
|
||
|
||
The reserved implicit operands include the symbols A, AB, C,
|
||
DPTR, PC, R0, R1, R2, R3, R4, R5, R6, R7, AR0, AR1, AR2, AR3,
|
||
AR4, AR5, AR6 and AR7. These symbols are used primarily as
|
||
instruction operands. Except for AB, C, DPTR or PC, these
|
||
symbols can also be used to define other symbols (see EQU
|
||
directive in Chapter 5).
|
||
|
||
The following are examples of illegal symbols with an explanation
|
||
of why they are illegal:
|
||
|
||
1ST_VARIABLE (Symbols can not start with a number.)
|
||
ALPHA# (Illegal character "#" in symbol.)
|
||
MOV (8051 instruction mnemonic)
|
||
LOW (Assembly operator)
|
||
DATA (Assembly directive)
|
||
|
||
|
||
2.3. Labels
|
||
|
||
Labels are special cases of symbols. Labels are used only before
|
||
statements that have physical addresses associated with them.
|
||
Examples of such statements are assembly language instructions,
|
||
data storage directives (DB and DW), and data reservation
|
||
directives (DS and DBIT). Labels must follow all the rules of
|
||
symbol creation with the additional requirement that they be
|
||
followed by a colon. The following are legal examples of label
|
||
uses:
|
||
|
||
TABLE_OF_CONTROL_CONSTANTS:
|
||
DB 0,1,2,3,4,5 (Data storage)
|
||
MESSAGE: DB 'HELP' (Data storage)
|
||
VARIABLES: DS 10 (Data reservation)
|
||
BIT_VARIABLES: DBIT 16 (Data reservation)
|
||
START: MOV A,#23 (Assembly language instruction)
|
||
|
||
|
||
|
||
|
||
2.4. Assembler Controls
|
||
|
||
|
||
|
||
2-2
|
||
|
||
|
||
|
||
|
||
Assembler controls are used to control where the Cross Assembler
|
||
gets its input source file, where it puts the object file, and
|
||
how it formats the listing file. Table 2-1 summarizes the
|
||
assembler controls available. Refer to Chapter 6 for a detailed
|
||
explanation of the controls.
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
Table 2-1: Summary of Cross Assembler Controls
|
||
|
||
|
||
As can be seen in Table 2-1, all assembler controls are prefaced
|
||
with a dollar sign ($). No spaces or tabs are allowed between the
|
||
dollar sign and the body of the control. Also, only one control
|
||
per line is permitted. However, comments can be on the same line
|
||
as a control. The following are examples of assembler controls:
|
||
|
||
$TITLE(8051 Program Ver. 1.0)
|
||
$LIST
|
||
$PAGEWIDTH(132)
|
||
|
||
|
||
2.5. Assembler Directives
|
||
|
||
Assembler directives are used to define symbols, reserve memory
|
||
space, store values in program memory and switch between
|
||
different memory spaces. There are also directives that set the
|
||
location counter for the active segment and identify the end of
|
||
the source file. Table 2-2 summarizes the assembler directives
|
||
available. These directives are fully explained in Chapter 5.
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
Table 2-2: Summary of Cross Assembler Directives
|
||
|
||
|
||
Only one directive per line is allowed, however comments may be
|
||
|
||
|
||
2-3
|
||
|
||
|
||
|
||
|
||
included. The following are examples of assembler directives:
|
||
|
||
TEN EQU 10
|
||
RESET CODE 0
|
||
ORG 4096
|
||
|
||
|
||
2.6. 8051 Instruction Mnemonics
|
||
|
||
The standard 8051 Assembly Language Instruction mnemonics plus
|
||
the generic CALL and JMP instructions are recognized by the Cross
|
||
Assembler and are summarized in Table 2-3. See Chapter 4 for the
|
||
operation of the individual instructions.
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
2-4
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
Table 2-3: 8051 Instructions and Mnemonics
|
||
|
||
When the Cross Assembler sees a generic CALL or JMP instruction,
|
||
it will try to translate the instruction into its most byte
|
||
efficient form. The Cross Assembler will translate a CALL into
|
||
one of two instructions (ACALL or LCALL) and it will translate a
|
||
generic JMP into one of three instructions (SJMP, AJMP or LJMP).
|
||
The choice of instructions is based on which one is most byte
|
||
efficient. The generic CALL or JMP instructions saves the
|
||
programmer the trouble of determining which form is best.
|
||
|
||
However, generic CALLs and JMPs do have their limitations. While
|
||
the byte efficiency algorithm works well for previously defined
|
||
locations, when the target location of the CALL or JMP is a forward
|
||
location (a location later on in the program), the assembler has no
|
||
way of determining the best form of the instruction. In this case
|
||
the Cross Assembler simply puts in the long version (LCALL or LJMP)
|
||
of the instruction, which may not be the most byte efficient. NOTE
|
||
that the generic CALLs and JMPs must not be used for the 751/752
|
||
device as LCALL and LJMP are not legal instructions for those
|
||
devices. Instead use ACALL and AJMP explicitly.
|
||
|
||
For instructions that have operands, the operands must be
|
||
separated from the mnemonic by at least one space or tab. For
|
||
instructions that have multiple operands, each operand must be
|
||
separated from the others by a comma.
|
||
|
||
Two addressing modes require the operands to be preceded by
|
||
special symbols to designate the addressing mode. The AT sign
|
||
(@) is used to designate the indirect addressing mode. It is
|
||
used primarily with Register 0 and Register 1 (R0, R1), but is
|
||
can also be used with the DPTR in the MOVX and the Accumulator in
|
||
MOVC and JMP @A+DPTR instructions. The POUND sign (#) is used to
|
||
designate an immediate operand. It can be used to preface
|
||
either a number or a symbol representing a number.
|
||
|
||
A third symbol used with the operands actually specifies an
|
||
operation. The SLASH (/) is used to specify that the contents of
|
||
a particular bit address is to be complemented before the
|
||
|
||
2-5
|
||
|
||
|
||
|
||
|
||
instruction operation. This is used with the ANL and ORL bit
|
||
instructions.
|
||
|
||
Only one assembly language instruction is allowed per line.
|
||
Comments are allowed on the same line as an instruction, but only
|
||
after all operands have been specified. The following are
|
||
examples of instruction statements:
|
||
|
||
START: LJMP INIT
|
||
MOV @R0,Serial_Port_Buffer
|
||
CJNE R0 , #TEN, INC_TEN
|
||
ANL C,/START_FLAG
|
||
CALL GET_BYTE
|
||
RET
|
||
|
||
|
||
2.7. Bit Addressing
|
||
|
||
The period (.) has special meaning to the Cross Assembler when
|
||
used in a symbol. It is used to explicitly specify a bit in a
|
||
bit-addressable symbol. For example, it you wanted to specify
|
||
the most significant bit in the Accumulator, you could write
|
||
ACC.7, where ACC was previously defined as the Accumulator
|
||
address. The same bit can also be selected using the physical
|
||
address of the byte it's in. For example, the Accumulator's
|
||
physical address is 224. The most significant bit of the
|
||
Accumulator can be selected by specifying 224.7. If the symbol
|
||
ON was defined to be equal to the value 7, you could also specify
|
||
the same bit by either ACC.ON or 224.ON.
|
||
|
||
|
||
2.8. ASCII Literals
|
||
|
||
Printable characters from the ASCII character set can be used
|
||
directly as an immediate operand, or they can used to define
|
||
symbols or store ASCII bytes in Program Memory. Such use of the
|
||
ASCII character set is called ASCII literals. ASCII literals are
|
||
identified by the apostrophe (') delimiter. The apostrophe
|
||
itself can be used as an ASCII literal. In this case, use two
|
||
apostrophes in a row. Below are examples of using ASCII
|
||
literals.
|
||
|
||
MOV A,#'m' ;Load A with 06DH (ASCII m)
|
||
QUOTE EQU '''' ;QUOTE defined as 27H (ASCII single quote)
|
||
DB '8051' ;Store in Program Memory
|
||
|
||
|
||
2.9. Comments
|
||
|
||
Comments are user defined character strings that are not
|
||
processed by the Cross Assembler. A comment begins with a
|
||
semicolon ( ; ) and ends at the carriage return/line feed pair
|
||
that terminates the line. A comment can appear anywhere in a
|
||
line, but it has to be the last field. The following are
|
||
examples of comment lines:
|
||
|
||
|
||
|
||
2-6
|
||
|
||
|
||
|
||
|
||
; Begin initialization routine here
|
||
$TITLE(8051 Program Vers. 1.0) ;Place version number here
|
||
TEN EQU 10 ;Constant
|
||
; Comment can begin anywhere in a line
|
||
MOV A,Serial_Port_Buffer ; Get character
|
||
|
||
|
||
2.10. The Location Counter
|
||
|
||
The Cross Assembler keeps a location counter for each of the five
|
||
segments (code, internal data, external data, indirect internal
|
||
data and bit data). Each location counter is initialized to zero
|
||
and can be modified using Assembler Directives described in
|
||
Chapter 5.
|
||
|
||
The dollar sign ($) can be used to specify the current value of
|
||
the location counter of the active segment. The following are
|
||
examples of how this can be used:
|
||
|
||
JNB FLAG,$ ;Jump on self until flag is reset
|
||
CPYRGHT: DB 'Copyright, 1983'
|
||
CPYRGHT_LENGTH
|
||
EQU $-CPYRGHT-1 ;Calculate length of copyright message
|
||
|
||
|
||
|
||
2.11. Syntax Summary
|
||
|
||
Since the Cross Assembler essentially translates the source file
|
||
on a line by line basis, certain rules must be followed to ensure
|
||
the translation process is done correctly. First of all, since
|
||
the Cross Assembler's line buffer is 256 characters deep, there
|
||
must always be a carriage return/line feed pair within the first
|
||
256 columns of the line.
|
||
|
||
A legal source file line must begin with either a control, a
|
||
symbol, a label, an instruction mnemonic, a directive, a comment
|
||
or it can be null (just the carriage return/line feed pair). Any
|
||
other beginning to a line will be flagged as an error.
|
||
|
||
While a legal source file line must begin with one of the above
|
||
items, the item doesn't have to begin in the first column of the
|
||
line. It only must be the first field of the line. Any number
|
||
(including zero) of spaces or tabs, up to the maximum line size,
|
||
may precede it.
|
||
|
||
Comments can be placed anywhere, but they must be the last field
|
||
in any line.
|
||
|
||
|
||
2.12. Numbers and Operators
|
||
|
||
The Cross Assembler accepts numbers in any one of four radices:
|
||
binary, octal, decimal and hexadecimal. To specify a number in a
|
||
specific radix, the number must use the correct digits for the
|
||
particular radix and immediately following the number with its
|
||
|
||
|
||
2-7
|
||
|
||
|
||
|
||
|
||
radix designator. Decimal is the default radix and the use of
|
||
its designator is optional. An hexadecimal number that would
|
||
begin with a letter digit must be preceded by a 0 (zero) to
|
||
distinguish it from a symbol. The internal representation of
|
||
numbers is 16-bits, which limits the maximum number possible.
|
||
Table 2-4 summarizes the radices available.
|
||
|
||
MAXIMUM LEGAL
|
||
RADIX DESIGNATOR LEGAL DIGITS NUMBER
|
||
----------- ---------- ------------ -----------------
|
||
Binary B 0,1 1111111111111111B
|
||
Octal O,Q 0,1,2,3,4,5, 177777O
|
||
6,7 177777Q
|
||
Decimal D,(default) 0,1,2,3,4,5, 65535D
|
||
6,7,8,9 65535
|
||
Hexadecimal H 0,1,2,3,4,5, 0FFFFH
|
||
6,7,8,9,A,B,
|
||
C,D,E,F
|
||
|
||
Table 2-4: Cross Assembler Radices
|
||
|
||
|
||
No spaces or tabs are allowed between the number and the radix
|
||
designator. The letter digits and radix designators can be in
|
||
upper or lower case. The following examples list the decimal
|
||
number 2957 in each of the available radices:
|
||
|
||
|
||
101110001101B (Binary)
|
||
5615o or 5615Q (Octal)
|
||
2957 or 2957D (Decimal)
|
||
0B8DH, 0b8dh (Hexadecimal)
|
||
|
||
When using radices with explicit bit symbols, the radix
|
||
designator follows the byte portion of the address as shown in
|
||
the following examples:
|
||
|
||
0E0H.7 Bit seven of hexadecimal address 0E0
|
||
200Q.ON Bit ON of octal address 200
|
||
|
||
The Cross Assembler also allows assembly time evaluation of
|
||
arithmetic expressions up to thirty-two levels of embedded
|
||
parentheses. All calculations use integer numbers and are done
|
||
in sixteen bit precision.
|
||
|
||
OPERATOR SYMBOL OPERATION
|
||
--------------- ------------------------
|
||
+ Addition
|
||
Unary positive
|
||
- Subtraction
|
||
Unary negation (2's complement)
|
||
* Multiplication
|
||
/ Integer division (no remainder)
|
||
MOD Modulus (remainder of integer division)
|
||
SHR Shift right
|
||
SHL Shift left
|
||
|
||
|
||
2-8
|
||
|
||
|
||
|
||
|
||
NOT Logical negation (1's complement)
|
||
AND Logical and
|
||
OR Inclusive or
|
||
XOR Exclusive or
|
||
LOW Low order 8-bits
|
||
HIGH High order 8-bits
|
||
EQ, = Relational equal
|
||
NE, <> Relational not equal
|
||
GT, > Relational greater than
|
||
GE, >= Relational greater than or equal
|
||
LT, < Relational less than
|
||
LE, <= Relational less than or equal
|
||
( ) Parenthetical statement
|
||
|
||
Table 2-5: Assembly Time Operations
|
||
|
||
|
||
The relational operators test the specified values and return
|
||
either a True or False. False is represented by a zero value,
|
||
True is represented by a non zero value (the True condition
|
||
actually returns a 16-bit value with every bit set; i.e.,
|
||
0FFFFH). The relational operators are used primarily with the
|
||
Conditional Assembly capability of the Cross Assembler.
|
||
|
||
Table 2-5 lists the operations available while Table 2-6 lists
|
||
the operations precedence in descending order. Operations with
|
||
higher precedence are done first. Operations with equal
|
||
precedence are evaluated from left to right.
|
||
|
||
OPERATION PRECEDENCE
|
||
--------- ----------
|
||
(,) HIGHEST
|
||
HIGH,LOW
|
||
*,/,MOD,SHR,SHL
|
||
+,-
|
||
EQ,LT,GT,LE,GE,NE,=,<,>,<=,>=,<>
|
||
NOT
|
||
AND
|
||
OR,XOR LOWEST
|
||
|
||
Table 2-6: Operators Precedence
|
||
|
||
|
||
The following are examples of all the available operations and
|
||
their result:
|
||
|
||
HIGH(0AADDH) will return a result of 0AAH
|
||
LOW(0AADDH) will return a result of 0DDH
|
||
7*4 will return a result of 28
|
||
7/4 will return a result of 1
|
||
7 MOD 4 will return a result of 3
|
||
1000B SHR 2 will return a result of 0010B
|
||
1010B SHL 2 will return a result of 101000B
|
||
10+5 will return a result of 15
|
||
+72 will return a result of 72
|
||
25-17 will return a result of 8
|
||
|
||
|
||
2-9
|
||
|
||
|
||
|
||
|
||
-1 will return a result of 1111111111111111B
|
||
NOT 1 will return a result of 1111111111111110B
|
||
7 EQ 4, 7 = 4 will return a result of 0
|
||
7 LT 4, 7 < 4 will return a result of 0
|
||
7 GT 4, 7 > 4 will return a result of 0FFFFH
|
||
7 LE 4, 7 <= 4 will return a result of 0
|
||
7 GE 4, 7 >= 4 will return a result of 0FFFFH
|
||
7 NE 4, 7 <> 4 will return a result of 0FFFFH
|
||
1101B AND 0101B will return a result of 0101B
|
||
1101B OR 0101B will return a result of 1101B
|
||
1101B XOR 0101B will return a result of 1000B
|
||
|
||
|
||
2.13. Source File Listing
|
||
|
||
The source file listing displays the results of the Cross
|
||
Assembler translation. Every line of the listing includes a copy
|
||
of the original source line as well as a line number and the
|
||
Cross Assembler translation.
|
||
|
||
For example, in translating the following line taken from the
|
||
middle of a source file:
|
||
|
||
TRANS: MOV R7,#32 ;Set up pointer
|
||
|
||
the listing will print:
|
||
|
||
002F 7920 152 TRANS: MOV R1,#32 ;Set up pointer
|
||
|
||
The '002F' is the current value of the location counter in
|
||
hexadecimal. The '7920' is the translated instruction, also in
|
||
hexadecimal. The '152' is the decimal line number of the current
|
||
assembly. After the line number is a copy of the source file
|
||
line that was translated.
|
||
|
||
Another example of a line in the listing file is as follows:
|
||
|
||
015B 13 =1 267 +2 RRC A
|
||
|
||
Here we see two additional fields. The '=1' before the line
|
||
number gives the current nesting of include files. The '+2'
|
||
after the line number gives the current macro nesting. This line
|
||
essentially says that this line comes from a second level nesting
|
||
of a macro that is part of an include file.
|
||
|
||
Another line format that is used in the listing is that of symbol
|
||
definition. In this case the location counter value and
|
||
translated instruction fields described above are replaced with
|
||
the definition of the symbol. The following are examples of
|
||
this:
|
||
|
||
00FF 67 MAX_NUM EQU 255
|
||
REG 68 COUNTER EQU R7
|
||
|
||
The '00FF' is the hexadecimal value of the symbol MAX_NUM.
|
||
Again, '67'is the decimal line number of the source file and the
|
||
|
||
|
||
2-10
|
||
|
||
|
||
|
||
|
||
remainder of the first line is a copy of the source file. In the
|
||
second line above, the 'REG' shows that the symbol COUNTER was
|
||
defined to be a general purpose register.
|
||
|
||
Optionally, a listing can have a page header that includes the
|
||
name of the file being assembled, title of program, date and page
|
||
number. The header and its fields are controlled by specific
|
||
Assembler Controls (see Chapter 6).
|
||
|
||
The default case is for a listing to be output as a file on the
|
||
default drive with the same name as the entered source file and
|
||
an extension of .LST. For example, if the source file name was
|
||
PROGRAM.ASM, the listing file would be called PROGRAM.LST. Or if
|
||
the source file was called MODULE1, the listing file would be
|
||
stored as MODULE1.LST. The default can be changed using the
|
||
$NOPRINT and $PRINT() Assembler Controls (see Chapter 6).
|
||
|
||
|
||
2.14. Object File
|
||
|
||
The 8051 Cross Assembler also creates a machine language object
|
||
file. The format of the object file is standard Intel
|
||
Hexadecimal. This Hexadeciaml file can be used to either program
|
||
EPROMs using standard PROM Programmers for prototyping, or used
|
||
to pattern masked ROMs for production.
|
||
|
||
The default case is for the object file to be output on the
|
||
default drive with the same name as the first source file and an
|
||
extension of .HEX. For example, if the source file name was
|
||
PROGRAM.ASM, the object file would be called PROGRAM.HEX. Or if
|
||
the source file was called MODULE1, the object file would be
|
||
stored as MODULE1.HEX. The default can be changed using the
|
||
$NOOBJECT and $OBJECT() Assembler Controls (see Chapter 6).
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
2-11
|
||
|
||
|
||
|
||
|
||
|
||
|
||
CHAPTER 3
|
||
|
||
|
||
RUNNING THE 8051 CROSS ASSEMBLER ON PC-DOS/MS-DOS SYSTEMS
|
||
|
||
3.1. Cross Assembler Files
|
||
|
||
The floppy disk you receive with this manual is an 8 sector,
|
||
single-sided, double density disk. This distribution disk will
|
||
contain the following files:
|
||
|
||
ASM51.EXE The Cross Assembler program itself
|
||
MOD152 Source file for the $MOD152 control
|
||
MOD154 Source file for the $MOD154 control
|
||
MOD252 Source file for the $MOD252 control
|
||
MOD44 Source file for the $MOD44 control
|
||
MOD451 Source file for the $MOD451 control
|
||
MOD452 Source file for the $MOD452 control
|
||
MOD51 Source file for the $MOD51 control
|
||
MOD512 Source file for the $MOD512 control
|
||
MOD515 Source file for the $MOD515 control
|
||
MOD517 Source file for the $MOD517 control
|
||
MOD52 Source file for the $MOD52 control
|
||
MOD521 Source file for the $MOD521 control
|
||
MOD552 Source file for the $MOD552 control
|
||
MOD652 Source file for the $MOD652 control
|
||
MOD751 Source file for the $MOD751 control
|
||
MOD752 Source file for the $MOD752 control
|
||
MOD851 Source file for the $MOD851 control
|
||
|
||
There will also be one or more files with an extension of .ASM.
|
||
These are sample programs. Listings of these programs can be
|
||
found in Appendix A.
|
||
|
||
DON'T USE THE DISTRIBUTION DISK. MAKE WORKING AND BACKUP COPIES
|
||
FROM THE DISTRIBUTION DISK AND THEN STORE THE DISTRIBUTION DISK
|
||
IN A SAFE PLACE.
|
||
|
||
|
||
3.2. Minimum System Requirements
|
||
|
||
With DOS 2.0 or later - 96K RAM
|
||
1 Floppy Disk Drive
|
||
|
||
|
||
3.3. Running the Cross Assembler
|
||
|
||
Once you've created an 8051 assembly language source text file in
|
||
accordance with the guidelines in Chapter 2, you are now ready to
|
||
run the Cross Assembler. Make sure your system is booted and the
|
||
DOS prompt ( A> ) appears on the screen. Place the disk with the
|
||
8051 Cross Assembler on it in the drive and simply type (in all
|
||
the following examples, the symbol <CR> is used to show where the
|
||
|
||
|
||
3-1
|
||
|
||
|
||
|
||
|
||
ENTER key was hit):
|
||
|
||
ASM51<CR>
|
||
|
||
|
||
If the 8051 Cross Assembler disk was placed in a drive other than
|
||
the default drive, the drive name would have to be typed first.
|
||
For example, if the A drive is the default drive, and the 8051
|
||
Cross Assembler is in the B drive, you would then type:
|
||
|
||
B:ASM51<CR>
|
||
|
||
After loading the program from the disk, the program's name, its
|
||
version number and general copyright information will be dis-
|
||
played on the screen. The Cross Assembler then asks for the
|
||
source file name to begin the assembly process.
|
||
|
||
Source file drive and name [.ASM]:
|
||
|
||
At this point, if you have only one floppy disk drive and the
|
||
8051 Cross Assembler and source files are on separate disks,
|
||
remove the disk with the 8051 Cross Assembler on it and replace
|
||
it with your source file disk.
|
||
|
||
Next, enter the source file name. If no extension is given, the
|
||
Cross Assembler will assume an extension of .ASM. If no drive is
|
||
given, the Cross Assembler will assume the default drive. Since
|
||
in every case where no drive is given, the Cross Assembler
|
||
assumes the default drive, it is generally a good practice to
|
||
change the default drive to the drive with your source files.
|
||
|
||
An alternative method for entering the source file is in the
|
||
command line. In this case, after typing in ASM51, type in a
|
||
space and the source file name (again if no extension is given,
|
||
source file on the command line:
|
||
|
||
A>ASM51 B:CONTROL.A51<CR>
|
||
|
||
After the source file name has been accepted, the Cross Assembler
|
||
will begin the translation process. As it starts the first pass
|
||
of its two pass process, it will print on the screen:
|
||
|
||
First pass
|
||
|
||
At the completion of the first pass, and as it starts its second
|
||
pass through the source file, the Cross Assembler will display:
|
||
|
||
Second pass
|
||
|
||
When second pass is completed, the translation process is done
|
||
and the Cross Assembler will print the following message:
|
||
|
||
ASSEMBLY COMPLETE, XX ERRORS FOUND
|
||
|
||
XX is replaced with the actual number of errors that were found.
|
||
Disk I/O may continue for a while as the Cross Assembler appends
|
||
|
||
|
||
3-2
|
||
|
||
|
||
|
||
|
||
the symbol table to the listing file.
|
||
|
||
|
||
3.4. Example Running the Cross Assembler
|
||
|
||
The following is an example of an actual run. The Cross
|
||
Assembler will take the source file SAMPLE.ASM from Drive A
|
||
(default drive).
|
||
|
||
Again, the symbol <CR> is used to show where the ENTER key was
|
||
hit.
|
||
|
||
A>ASM51<CR>
|
||
|
||
|
||
|
||
|
||
8 0 5 1 C R O S S A S S E M B L E R
|
||
|
||
|
||
Version 1.2
|
||
|
||
(c) Copyright 1984, 1985, 1986, 1987, 1988, 1989, 1990
|
||
|
||
MetaLink Corporation
|
||
|
||
|
||
|
||
Source file drive and name [.ASM]: sample<CR>
|
||
|
||
First pass
|
||
|
||
Second pass
|
||
|
||
ASSEMBLY COMPLETE, 0 ERRORS FOUND
|
||
|
||
|
||
3.5. DOS Hints and Suggestions
|
||
|
||
If you are using DOS 2.0 or later, you may want to use the BREAK
|
||
ON command before you run the Cross Assembler. This will allow
|
||
you to abort (Ctrl-Break) the Cross Assembler at any time.
|
||
Otherwise, you will only be able to abort the Cross Assembler
|
||
after it completes a pass through the source file. If you are
|
||
assembling a large file, this could cause you a several minute
|
||
wait before the Cross Assembler aborts.
|
||
|
||
The reason for this it that the default condition for DOS to
|
||
recognizes a Ctrl-Break is when the program (in this case the
|
||
Cross Assembler) does keyboard, screen or printer I/O.
|
||
Unfortunately, the assembler does this very rarely (once each
|
||
pass). By using the BREAK ON command, DOS will recognize a Ctrl-
|
||
Break for all I/O, including disk I/O. Since the Cross Assembler
|
||
is constantly doing disk I/O, with BREAK ON you can abort almost
|
||
immediately by hitting the Ctrl-Break keys.
|
||
|
||
|
||
|
||
3-3
|
||
|
||
|
||
|
||
|
||
So much for the good news. However, aborting a program can cause
|
||
some undesirable side-effects. Aborting a program while files
|
||
are open causes DOS to drop some information about the open
|
||
files. This results in disk sectors being allocated when they
|
||
are actually free. Your total available disk storage shrinks.
|
||
You should make the practice of running CHKDSK with the /F switch
|
||
periodically to recover these sectors.
|
||
|
||
The Cross Assembler run under DOS 2.0 or later supports
|
||
redirection. You can specify the redirection on the command line.
|
||
Use the following form:
|
||
|
||
ASM51 <infile >outfile
|
||
|
||
"infile" and "outfile" can be any legal file designator. The
|
||
Cross Assembler will take its input from the "infile" instead of
|
||
the keyboard and will send its output to "outfile" instead of the
|
||
screen.
|
||
|
||
Note that redirection of input in ASM51 is redundant since the
|
||
assembler is an absolute assembler and has no command line
|
||
options other than the file name argument.
|
||
|
||
Output redirection is useful for speeding up the assembly
|
||
process. Because assembly-time errors are directed to std_err in
|
||
DOS, an error listing cannot be redirected to a file
|
||
|
||
To make the .lst file serve as an error-only file, use the Cross
|
||
Assembler Controls $PRINT (create a list file) $NOLIST (turn the
|
||
listing off). Use the Cross Assembler Controls $NOSYMBOLS to
|
||
further compress the error-only listing resulting from the
|
||
manipulation of the list file controls. See Chapter 6 for more
|
||
information. The errors will be listed in the .lst file, as
|
||
usual.
|
||
|
||
If the control $NOPRINT (see Chapter 6) is active, all error
|
||
messages are send to the screen.
|
||
|
||
|
||
|
||
3.6. References
|
||
|
||
1. IBM Corp., Disk Operating System, Version 1.10, May 1982.
|
||
2. IBM Corp., Disk Operating System, Version 2.00, January 1983.
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
3-4
|
||
|
||
|
||
|
||
|
||
CHAPTER 4
|
||
|
||
|
||
8051 INSTRUCTION SET
|
||
|
||
|
||
4.1. Notation
|
||
|
||
Below is an explanation of the column headings and column
|
||
contents of the 8051 Instruction Set Summary Table that follows
|
||
in this chapter.
|
||
|
||
|
||
MNEMONIC
|
||
|
||
The MNEMONIC column contains the 8051 Instruction Set Mnemonic
|
||
and a brief description of the instruction's operation.
|
||
|
||
|
||
OPERATION
|
||
|
||
The OPERATION column describes the 8051 Instruction Set in unam-
|
||
biguous symbology. Following are the definitions of the symbols
|
||
used in this column.
|
||
|
||
<n:m> Bits of a register inclusive. For
|
||
example, PC<10:0> means bits 0 through 10
|
||
inclusive of the PC. Bit 0 is always the
|
||
least significant bit.
|
||
+ Binary addition
|
||
- Binary 2s complement subtraction
|
||
/ Unsigned integer division
|
||
X Unsigned integer multiplication
|
||
~ Binary complement (1s complement)
|
||
^ Logical And
|
||
v Inclusive Or
|
||
v Exclusive Or
|
||
> Greater than
|
||
<> Not equal to
|
||
= Equals
|
||
-> Is written into. For example, A + SOper -
|
||
> A means the result of the binary
|
||
addition between A and the Source Operand
|
||
is written into A.
|
||
|
||
A The 8-bit Accumulator Register.
|
||
AC The Auxiliary Carry Flag in the Program
|
||
Status Word
|
||
CF The Carry Flag in the Program Status Word
|
||
DOper The Destination Operand used in the
|
||
instruction.
|
||
DPTR 16-bit Data Pointer
|
||
Intrupt Active Flag Internal Flag that holds off interrupts
|
||
|
||
|
||
4-1
|
||
|
||
|
||
|
||
until the Flag is cleared.
|
||
Jump Relative to PC A Jump that can range between -128 bytes
|
||
and +127 bytes from the PC value of
|
||
the next instruction.
|
||
Paddr A 16-bit Program Memory address
|
||
PC The 8051 Program Counter. This 16-bit
|
||
register points to the byte in the
|
||
Program Memory space that is fetched as
|
||
part of the instruction stream.
|
||
PM(addr) Byte in Program Memory space pointed
|
||
to by addr.
|
||
Remainder Integer remainder of unsigned integer division
|
||
SOper The Source Operand used in the instruction.
|
||
SP 8-bit Stack Pointer
|
||
STACK The Last In First Out data structure that
|
||
is controlled by the 8-bit Stack
|
||
Pointer (SP). Sixteen bit quantities are
|
||
pushed on the stack low byte first.
|
||
|
||
|
||
DEST ADDR MODE/SOURCE ADDR MODE
|
||
|
||
These two columns specify the Destination and Source Addressing
|
||
Modes, respectively, that are available for each instruction.
|
||
|
||
AB The Accumulator-B Register pair.
|
||
Accumulator Operand resides in the accumulator
|
||
Bit Direct Operand is the state of the bit specified by the
|
||
Bit Memory address.
|
||
Carry Flag Operand is the state of the 1-bit Carry flag in
|
||
the Program Status Word (PSW).
|
||
Data Pointer Operand resides in the 16-bit Data Pointer
|
||
Register.
|
||
Direct Operand is the contents of the specified 8-bit
|
||
Internal Data Memory address from 0
|
||
(00H) to 127 (7FH) or a Special Function Register
|
||
address.
|
||
Indirect Operand is the contents of the address contained
|
||
in the register specified.
|
||
Immediate Operand is the next sequential byte after the
|
||
instruction in Program Memory space
|
||
Prog Direct 16-bit address in Program Memory Space.
|
||
Prog Indir Operand in Program Memory Space is the address
|
||
contained in the register specified.
|
||
Register Operand is the contents of the register specified.
|
||
Stack Operand is on the top of the Stack.
|
||
|
||
|
||
ASSEMBLY LANGUAGE FORM
|
||
|
||
This column contains the correct format of the instructions that
|
||
are recognized by the Cross Assembler.
|
||
|
||
A Accumulator
|
||
AB Accumulator-B Register pair.
|
||
|
||
4-2
|
||
|
||
|
||
|
||
|
||
C Carry Flag
|
||
Baddr Bit Memory Direct Address.
|
||
Daddr Internal Data Memory or Special Function Register
|
||
Direct Address.
|
||
data 8-bit constant data.
|
||
data16 16-bit constant data.
|
||
DPTR 16-bit Data Pointer Register.
|
||
PC 16-bit Program Counter.
|
||
Paddr 16-bit Program Memory address
|
||
Ri Indirect Register. R0 or R1 are the only indirect
|
||
registers.
|
||
Roff 8-bit offset for Relative Jump.
|
||
Rn Implicit Register. Each register bank has 8 general
|
||
purpose registers, designated R0, R1, R2, R3,
|
||
R4, R5, R6, R7.
|
||
|
||
|
||
HEX OPCODE
|
||
|
||
This column gives the machine language hexadecimal opcode for
|
||
each 8051 instruction.
|
||
|
||
|
||
|
||
BYT
|
||
|
||
This column gives the number of bytes in each 8051 instruction.
|
||
|
||
|
||
CYC
|
||
|
||
This column gives the number of cycles of each 8051 instruction.
|
||
The time value of a cycle is defined as 12 divided by the
|
||
oscillator frequency. For example, if running an 8051 family
|
||
component at 12 MHz, each cycle takes 1 microsecond.
|
||
|
||
|
||
PSW
|
||
|
||
This column identifies which condition code flags are affected by
|
||
the operation of the individual instructions. The condition code
|
||
flags available on the 8051 are the Carry Flag, CF, the Auxiliary
|
||
Carry Flag, AC, and the Overflow Flag, OV.
|
||
|
||
It should be noted that the PSW is both byte and bit directly
|
||
addressable. Should the PSW be the operand of an instruction
|
||
that modifies it, the condition codes could be changed even if
|
||
this column states that the instruction doesn't affect them.
|
||
|
||
0 Condition code is cleared
|
||
1 Condition code is set
|
||
* Condition code is modified by instruction
|
||
- Condition code is not affected by instruction
|
||
|
||
4.2. 8051 Instruction Set Summary
|
||
|
||
|
||
|
||
4-3
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
4-4
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
4-5
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
4-6
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
4-7
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
4-8
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
4-9
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
4-10
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
4-11
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
4-12
|
||
|
||
|
||
|
||
|
||
4.3. Notes
|
||
|
||
|
||
1 There are 8 possible opcodes. Starting with 11H as the
|
||
opcode base, the final opcode is formed by placing bits 8, 9 and
|
||
10 of the target address in bits 5, 6 and 7 of the opcode. The 8
|
||
possible opcodes in hexadecimal are then: 11, 31, 51, 71, 91, B1,
|
||
D1, F1.
|
||
|
||
2 There are 8 possible opcodes. Starting with 01H as
|
||
the opcode base, the final opcode is formed by placing bits 8, 9
|
||
and 10 of the target address in bits 5, 6 and 7 of the opcode.
|
||
The 8 possible opcodes in hexadecimal are then: 01, 21, 41, 61,
|
||
81, A1, C1, E1.
|
||
|
||
3 The Carry Flag is set if the Destination Operand is
|
||
less than the Source Operand. Otherwise the Carry Flag is
|
||
cleared.
|
||
|
||
4 The Carry Flag is set if the BCD result in the
|
||
Accumulator is greater than decimal 99.
|
||
|
||
5 The Overflow Flag is set if the B Register contains
|
||
zero (flags a divide by zero operation). Otherwise the Overflow
|
||
Flag is cleared.
|
||
|
||
6 If any of the condition code flags are specified as
|
||
the operand of this instruction, they will be reset by the
|
||
instruction if they were originally set.
|
||
|
||
7 The high byte of the 16-bit product is placed in the
|
||
B Register, the low byte in Accumulator.
|
||
|
||
|
||
4.4. References
|
||
|
||
1. Intel Corp., Microcontroller Handbook, 1984.
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
4-13
|
||
|
||
|
||
|
||
|
||
|
||
|
||
CHAPTER 5
|
||
|
||
|
||
8051 CROSS ASSEMBLER DIRECTIVES
|
||
|
||
5.1. Introduction
|
||
|
||
The 8051 Cross Assembler Directives are used to define symbols,
|
||
reserve memory space, store values in program memory, select
|
||
various memory spaces, set the current segment's location counter
|
||
and identify the end of the source file.
|
||
|
||
Only one directive per line is allowed, however comments may be
|
||
included. The remaining part of this chapter details the
|
||
function of each directive.
|
||
|
||
|
||
5.2. Symbol Definition Directives
|
||
|
||
EQU Directive
|
||
|
||
The EQUate directive is used to assign a value to a symbol. It
|
||
can also be used to specify user defined names for the implicit
|
||
operand symbols predefined for the Accumulator (i.e., A) and the
|
||
eight General Purpose Registers (i.e., R0 thru R7).
|
||
|
||
The format for the EQU directive is: symbol, followed by one or
|
||
more spaces or tabs, followed by EQU, followed by one or more
|
||
spaces or tabs, followed by a number, arithmetic expression,
|
||
previously defined symbol (no forward references allowed) or one
|
||
of the allowed implicit operand symbols (e.g., A, R0, R1, R2, R3,
|
||
R4, R5, R6, R7), followed by an optional comment.
|
||
|
||
Below are examples of using the EQU Directive:
|
||
|
||
TEN EQU 10 ;Symbol equated to a number
|
||
COUNTER EQU R7 ;User defined symbol for the implicit
|
||
;operand symbol R7. COUNTER can now
|
||
;be used wherever it is legal to use
|
||
;R7. For example the instruction
|
||
;INC R7 could now be written INC COUNTER.
|
||
ALSO_TEN EQU TEN ;Symbol equated to a previously defined
|
||
;symbol.
|
||
FIVE EQU TEN/2 ;Symbol equated to an arithmetic exp.
|
||
A_REG EQU A ;User defined symbol for the implicit
|
||
;operand symbol A.
|
||
ASCII_D EQU 'D' ;Symbol equated to an ASCII literal
|
||
|
||
|
||
SET Directive
|
||
|
||
Similar to the EQU directive, the SET directive is used to assign
|
||
a value or implicit operand to a user defined symbol. The
|
||
difference however, is that with the EQU directive, a symbol can
|
||
|
||
|
||
5-1
|
||
|
||
|
||
|
||
|
||
only be defined once. Any attempt to define the symbol again
|
||
will cause the Cross Assembler to flag it as an error. On the
|
||
other hand, with the SET directive, symbols are redefineable.
|
||
There is no limit to the number of times a symbol can be
|
||
redefined with the SET directive.
|
||
|
||
The format for the SET directive is: symbol, followed by one or
|
||
more spaces or tabs, followed by SET, followed by one or more
|
||
spaces or tabs, followed by a number, arithmetic expression,
|
||
previously defined symbol (no forward references allowed) or one
|
||
of the allowed implicit operand symbols (e.g., A, R0, R1, R2, R3,
|
||
R4, R5, R6, R7), followed by an optional comment.
|
||
|
||
Below are examples of using the SET Directive:
|
||
|
||
POINTER SET R0 ;Symbol equated to register 0
|
||
POINTER SET R1 ;POINTER redefined to register 1
|
||
|
||
COUNTER SET 1 ;Symbol initialized to 1
|
||
COUNTER SET COUNTER+1 ;An incrementing symbol
|
||
|
||
|
||
BIT Directive
|
||
|
||
The BIT Directive assigns an internal bit memory direct address
|
||
to the symbol. If the numeric value of the address is between 0
|
||
and 127 decimal, it is a bit address mapped in the Internal
|
||
Memory Space. If the numeric value of the address is between 128
|
||
and 255, it is an address of a bit located in one of the Special
|
||
Function Registers. Addresses greater than 255 are illegal and
|
||
will be flagged as an error.
|
||
|
||
The format for the BIT Directive is: symbol, followed by one or
|
||
more spaces or tabs, followed by BIT, followed by one or more
|
||
spaces or tabs, followed by a number, arithmetic expression, or
|
||
previously defined symbol (no forward references allowed),
|
||
followed by an optional comment.
|
||
|
||
Below are examples of using the BIT Directive:
|
||
|
||
CF BIT 0D7H ;The single bit Carry Flag in PSW
|
||
OFF_FLAG BIT 6 ;Memory address of single bit flag
|
||
ON_FLAG BIT OFF_FLAG+1 ;Next bit is another flag
|
||
|
||
|
||
CODE Directive
|
||
|
||
The CODE Directive assigns an address located in the Program
|
||
Memory Space to the symbol. The numeric value of the address
|
||
cannot exceed 65535.
|
||
|
||
The format for the CODE Directive is: symbol, followed by one or
|
||
more spaces or tabs, followed by CODE, followed by one or more
|
||
spaces or tabs, followed by a number, arithmetic expression, or
|
||
previously defined symbol (no forward references allowed),
|
||
followed by an optional comment.
|
||
|
||
|
||
5-2
|
||
|
||
|
||
|
||
|
||
Below are examples of using the CODE Directive:
|
||
|
||
RESET CODE 0
|
||
EXTI0 CODE RESET + (1024/16)
|
||
|
||
|
||
DATA Directive
|
||
|
||
The DATA Directive assigns a directly addressable internal memory
|
||
address to the symbol. If the numeric value of the address is
|
||
between 0 and 127 decimal, it is an address of an Internal Data
|
||
Memory location. If the numeric value of the address is between
|
||
128 and 255, it is an address of a Special Function Register.
|
||
Addresses greater than 255 are illegal and will be flagged as an
|
||
error.
|
||
|
||
The format for the DATA Directive is: symbol, followed by one or
|
||
more spaces or tabs, followed by DATA, followed by one or more
|
||
spaces or tabs, followed by a number, arithmetic expression, or
|
||
previously defined symbol (no forward references allowed),
|
||
followed by an optional comment.
|
||
|
||
Below are examples of using the DATA Directive:
|
||
|
||
PSW DATA 0D0H ;Defining the Program Status address
|
||
BUFFER DATA 32 ;Internal Data Memory address
|
||
FREE_SPAC DATA BUFFER+16 ;Arithmetic expression.
|
||
|
||
|
||
IDATA Directive
|
||
|
||
The IDATA Directive assigns an indirectly addressable internal
|
||
data memory address to the symbol. The numeric value of the
|
||
address can be between 0 and 255 decimal. Addresses greater than
|
||
255 are illegal and will be flagged as an error.
|
||
|
||
The format for the IDATA Directive is: symbol, followed by one or
|
||
more spaces or tabs, followed by IDATA, followed by one or more
|
||
spaces or tabs, followed by a number, arithmetic expression, or
|
||
previously defined symbol (no forward references allowed),
|
||
followed by an optional comment.
|
||
|
||
Below are examples of using the IDATA Directive:
|
||
|
||
TOKEN IDATA 60
|
||
BYTE_CNT IDATA TOKEN + 1
|
||
ADDR IDATA TOKEN + 2
|
||
|
||
|
||
XDATA Directive
|
||
|
||
The XDATA Directive assigns an address located in the External
|
||
Data Memory Space to the symbol. The numeric value of the
|
||
address cannot exceed 65535.
|
||
|
||
|
||
|
||
5-3
|
||
|
||
|
||
|
||
|
||
The format for the XDATA Directive is: symbol, followed by one or
|
||
more spaces or tabs, followed by XDATA, followed by one or more
|
||
spaces or tabs, followed by a number, arithmetic expression, or
|
||
previously defined symbol (no forward references allowed),
|
||
followed by an optional comment.
|
||
|
||
Below are examples of using the XDATA Directive:
|
||
|
||
USER_BASE XDATA 2048
|
||
HOST_BASE XDATA USER_BASE + 1000H
|
||
|
||
|
||
5.3. Segment Selection Directives
|
||
|
||
There are five Segment Selection Directives: CSEG, BSEG, DSEG,
|
||
ISEG, XSEG, one for each of the five memory spaces in the 8051
|
||
architecture. The CSEG Directive is used to select the Program
|
||
Memory Space. The BSEG Directive is used to select the Bit
|
||
Memory Space. The DSEG Directive is used to select the directly
|
||
addressable Internal Data Memory Space. The ISEG is used to
|
||
select the indirectly addressable Internal Data Memory Space.
|
||
The XSEG is used to select the External Data Memory Space.
|
||
|
||
Each segment has its own location counter that is reset to zero
|
||
during the Cross Assembler program initialization. The contents
|
||
of the location counter can be overridden by using the optional
|
||
AT after selecting the segment.
|
||
|
||
The Program Memory Space, or CSEG, is the default segment and is
|
||
selected when the Cross Assembler is run.
|
||
|
||
The format of the Segment Selection Directives are: zero or more
|
||
spaces or tabs, followed by the Segment Selection Directive,
|
||
followed by one or more spaces or tabs, followed by the optional
|
||
segment location counter override AT command and value, followed
|
||
by an optional comment.
|
||
|
||
The value of the AT command can be a number, arithmetic
|
||
expression or previously defined symbol (forward references are
|
||
not allowed). Care should be taken to ensure that the location
|
||
counter does not advance beyond the limit of the selected
|
||
segment.
|
||
|
||
Below are examples of the Segment Selection Directives:
|
||
|
||
DSEG ;Select direct data segment using
|
||
;current location counter value.
|
||
BSEG AT 32 ;Select bit data segment forcing
|
||
;location counter to 32 decimal.
|
||
XSEG AT (USER_BASE * 5) MOD 16 ;Arithmetic expressions can be
|
||
;used to specify location.
|
||
|
||
|
||
5.4. Memory Reservation and Storage Directives
|
||
|
||
|
||
|
||
5-4
|
||
|
||
|
||
|
||
|
||
DS Directive
|
||
|
||
The DS Directive is used to reserve space in the currently
|
||
selected segment in byte units. It can only be used when ISEG,
|
||
DSEG or XSEG are the currently active segments. The location
|
||
counter of the segment is advanced by the value of the directive.
|
||
Care should be taken to ensure that the location counter does not
|
||
advance beyond the limit of the segment.
|
||
|
||
The format for the DS Directive is: optional label, followed by
|
||
one or more spaces or tabs, followed by DS, followed by one or
|
||
more spaces or tabs, followed by a number, arithmetic expression,
|
||
or previously defined symbol (no forward references allowed),
|
||
followed by an optional comment.
|
||
|
||
Below is an example of using the DS Directive in the internal
|
||
Data Segment. If, for example, the Data Segment location counter
|
||
contained 48 decimal before the example below, it would contain
|
||
104 decimal after processing the example.
|
||
|
||
DSEG ;Select the data segment
|
||
DS 32 ;Label is optional
|
||
SP_BUFFER: DS 16 ;Reserve a buffer for the serial port
|
||
IO_BUFFER: DS 8 ;Reserve a buffer for the I/O
|
||
|
||
|
||
DBIT Directive
|
||
|
||
The DBIT Directive is used to reserve bits within the BIT
|
||
segment. It can only be used when BSEG is the active segment.
|
||
The location counter of the segment is advanced by the value of
|
||
the directive. Care should be taken to ensure that the location
|
||
counter does not advance beyond the limit of the segment.
|
||
|
||
The format for the DBIT Directive is: optional label, followed by
|
||
one or more spaces or tabs, followed by DBIT, followed by one or
|
||
more spaces or tabs, followed by a number, arithmetic expression,
|
||
or previously defined symbol (no forward references allowed),
|
||
followed by an optional comment.
|
||
|
||
Below is an example of using the DBIT Directive:
|
||
|
||
BSEG ;Select the bit segment
|
||
DBIT 16 ;Label is optional
|
||
IO_MAP: DBIT 32 ;Reserve a bit buffer for I/O
|
||
|
||
|
||
DB Directive
|
||
|
||
The DB Directive is used to store byte constants in the Program
|
||
Memory Space. It can only be used when CSEG is the active
|
||
segment.
|
||
|
||
The format for the DB Directive is: optional label, followed by
|
||
one or more spaces or tabs, followed by DB, followed by one or
|
||
more spaces or tabs, followed by the byte constants that are
|
||
|
||
|
||
5-5
|
||
|
||
|
||
|
||
|
||
separated by commas, followed by an optional comment.
|
||
|
||
The byte constants can be numbers, arithmetic expressions, symbol
|
||
values or ASCII literals. ASCII literals have to be delimited by
|
||
apostrophes ( ' ), but they can be strung together up to the
|
||
length of the line.
|
||
|
||
Below are examples of using the DB Directive. If an optional
|
||
label is used, its value will point to the first byte constant
|
||
listed.
|
||
|
||
COPYRGHT_MSG:
|
||
DB '(c) Copyright, 1984' ;ASCII Literal
|
||
RUNTIME_CONSTANTS:
|
||
DB 127,13,54,0,99 ;Table of constants
|
||
DB 17,32,239,163,49 ;Label is optional
|
||
MIXED: DB 2*8,'MPG',2*16,'abc' ;Can mix literals & no.
|
||
|
||
|
||
DW Directive
|
||
|
||
The DW Directive is used to store word constants in the Program
|
||
Memory Space. It can only be used when CSEG is the active
|
||
segment.
|
||
|
||
The format for the DW Directive is: optional label, followed by
|
||
one or more spaces or tabs, followed by DW, followed by one or
|
||
more spaces or tabs, followed by the word constants that are
|
||
separated by commas, followed by an optional comment.
|
||
|
||
The word constants can be numbers, arithmetic expressions, symbol
|
||
values or ASCII literals. ASCII literals must be delimited by
|
||
apostrophes ( ' ), but unlike the DB Directive, only a maximum of
|
||
two ASCII characters can be strung together. The first character
|
||
is placed in the high byte of the word and the second character
|
||
is placed in the low byte. If only one character is enclosed by
|
||
the apostrophes, a zero will be placed in the high byte of the
|
||
word.
|
||
|
||
Below are examples of using the DW Directive. If an optional
|
||
label is used, its value will point to the high byte of the first
|
||
word constant listed.
|
||
|
||
JUMP_TABLE: DW RESET,START,END ;Table of addresses
|
||
DW TEST,TRUE,FALSE ;Optional label
|
||
RADIX: DW 'H',1000H ;1st byte contains 0
|
||
;2nd byte contains 48H (H)
|
||
;3rd byte contains 10H
|
||
;4th byte contains 0
|
||
|
||
|
||
5.5. Miscellaneous Directives
|
||
|
||
|
||
ORG Directive
|
||
|
||
|
||
|
||
5-6
|
||
|
||
|
||
|
||
|
||
The ORG Directive is used to specify a value for the currently
|
||
active segment's location counter. It cannot be used to select
|
||
segments like the directives above. It can only be used within a
|
||
segment when the location counter needs to be changed. Care
|
||
should be taken to ensure that the location counter does not
|
||
advance beyond the limit of the selected segment.
|
||
|
||
The format of the ORG Directive is: zero or more spaces or tabs,
|
||
followed by ORG, followed by one or more spaces or tabs, followed
|
||
by a number, arithmetic expression, or previously defined symbol
|
||
(no forward references are allowed), followed by an optional
|
||
comment.
|
||
|
||
Below are examples of the ORG directive.
|
||
|
||
ORG 1000H ;Location counter set at 4096 decimal
|
||
ORG RESET ;Previously defined symbol
|
||
ORG BASE + MODULE_NO ;Arithmetic expression
|
||
|
||
|
||
USING DIRECTIVE
|
||
|
||
The USING Directive is used to specify which of the four General
|
||
Purpose Register banks is used in the code that follows the
|
||
directive. It allows the use of the predefined register symbols
|
||
AR0 thru AR7 instead of the register's direct addresses. It
|
||
should be noted that the actual register bank switching must
|
||
still be done in the code. This directive simplifies the direct
|
||
addressing of a specified register bank.
|
||
|
||
The format of the USING Directive is: zero or more spaces or
|
||
tabs, followed by USING, followed by one or more spaces or tabs,
|
||
followed by a number, arithmetic expression, or previously
|
||
defined symbol (no forward references are allowed), followed by
|
||
an optional comment.
|
||
|
||
The number, arithmetic expression, or previously defined symbol
|
||
must result in a number between 0 and 3 in order to specify one
|
||
of the four register banks in the 8051.
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
5-7
|
||
|
||
|
||
|
||
|
||
The following table maps the specified value in the USING
|
||
directive with the direct addresses of the predefined symbols.
|
||
|
||
Predefined | USING Value |
|
||
Symbol | 0 1 2 3 |
|
||
-----------------------------------------------
|
||
AR0 0 8 16 24
|
||
AR1 1 9 17 25
|
||
AR2 2 10 18 26
|
||
AR3 3 11 19 27
|
||
AR4 4 12 20 28
|
||
AR5 5 13 21 29
|
||
AR6 6 14 22 30
|
||
AR7 7 15 23 31
|
||
|
||
|
||
Below are examples of the USING Directive:
|
||
|
||
USING 0 ;Select addresses for Bank 0
|
||
USING 1+1+1 ;Arithmetic expressions
|
||
|
||
|
||
END Directive
|
||
|
||
The END Directive is used to signal the end of the source program
|
||
to the Cross Assembler. Every source program must have one and
|
||
only one END Directive. A missing END Directive, as well as text
|
||
beyond the occurrence of the END Directive are not allowed and
|
||
will be flagged as errors.
|
||
|
||
The format of the END Directive is: zero or more spaces or tabs,
|
||
followed by END, followed by an optional comment. All text must
|
||
appear in the source program before the occurrence of the END
|
||
Directive.
|
||
|
||
Below is an example of the END Directive:
|
||
|
||
END ;This is the End
|
||
|
||
|
||
5.6. Conditional Assembly Directives
|
||
|
||
IF, ELSE and ENDIF Directive
|
||
|
||
The IF, ELSE and ENDIF directives are used to define conditional
|
||
assembly blocks. A conditional assembly block begins with an IF
|
||
statement and must end with the ENDIF directive. In between the
|
||
IF statement and ENDIF directive can be any number of assembly
|
||
language statements, including directives, controls,
|
||
instructions, the ELSE directive and nested IF-ENDIF conditional
|
||
assembly blocks.
|
||
|
||
The IF statement starts with the keyword IF, followed by one or
|
||
more spaces or tabs, followed by a number, arithmetic expression,
|
||
or previously defined symbol (no forward references are allowed),
|
||
followed by an optional comment. The number, arithmetic
|
||
|
||
|
||
5-8
|
||
|
||
|
||
|
||
|
||
expression or symbol is evaluated and if found to be TRUE (non-
|
||
zero), the assembly language statements are translated up to the
|
||
next ELSE or ENDIF directives. If the IF statement was evaluated
|
||
FALSE (zero), the assembly language statements are considered
|
||
null up to the next ELSE or ENDIF directives.
|
||
|
||
If an optional ELSE appears in the conditional assembly block,
|
||
the assembly language statements following are handled oppositely
|
||
from the assembly language statements following the IF statement.
|
||
In other words, if the IF statement was evaluated TRUE, the
|
||
statements following it are translated, while the statements
|
||
following the ELSE will be handled as if they were null. On the
|
||
other hand, if the IF statement was evaluated FALSE, only the
|
||
assembly language statements following the ELSE directive would
|
||
be translated.
|
||
|
||
IF-ELSE-ENDIF conditional assembly blocks can be nested up to 255
|
||
levels deep. The following are some examples of conditional
|
||
assembly blocks. This first conditional assembly block simply
|
||
checks the symbol DEBUG. If DEBUG is non-zero, the MOV and CALL
|
||
instructions will be translated by the Cross Assembler.
|
||
|
||
IF (DEBUG)
|
||
MOV A,#25
|
||
CALL OUTPUT
|
||
ENDIF
|
||
|
||
The next example used the optional ELSE directive. If
|
||
SMALL_MODEL is zero, only the statements following the ELSE
|
||
directive will be translated.
|
||
|
||
IF (SMALL_MODEL)
|
||
MOV R0,#BUFFER
|
||
MOV A,@R0
|
||
ELSE
|
||
MOV R0,#EXT_BUFFER
|
||
MOVX A,@R0
|
||
ENDIF
|
||
|
||
The last example shows nested conditional assembly blocks.
|
||
Conditional assembly blocks can be nested up to 255 levels deep.
|
||
Every level of nesting must have balanced IF-ENDIF statements.
|
||
_
|
||
IF (VERSION > 10) \
|
||
CALL DOUBLE_PRECISION |
|
||
CALL UPDATE_STATUS _ |
|
||
IF (DEBUG) \ |
|
||
CALL DUMP_REGISTERS > Nested |
|
||
ENDIF _/ Block |
|
||
ELSE > Outer Block
|
||
CALL SINGLE_PRECISION |
|
||
CALL UPDATE_STATUS _ |
|
||
IF (DEBUG) \ |
|
||
CALL DUMP_REGISTERS > Nested |
|
||
ENDIF _/ Block |
|
||
ENDIF _/
|
||
|
||
5-9
|
||
|
||
|
||
|
||
|
||
|
||
|
||
CHAPTER 6
|
||
|
||
|
||
8051 CROSS ASSEMBLER CONTROLS
|
||
|
||
|
||
6.1. Introduction
|
||
|
||
Assembler controls are used to control where the Cross Assembler
|
||
gets its input source file, where it stores the object file, how
|
||
it formats and where it outputs the listing.
|
||
|
||
All Assembler controls are prefaced with a dollar sign, ($). No
|
||
spaces or tabs are allowed between the dollar sign and the body
|
||
of the control. Also, only one control per line is permitted.
|
||
Comments are allowed on the same line as an Assembler control.
|
||
|
||
There are two types of controls, Primary controls and General
|
||
controls. Primary controls can be invoked only once per
|
||
assembly. If an attempt is made to change a previously invoked
|
||
primary control, the attempt is ignored. For example, if
|
||
$NOPRINT is put on line 1 of the source file and $PRINT is put on
|
||
line 2, the $PRINT control will be ignored and the listing will
|
||
not be output. General controls can be invoked any number of
|
||
times in a source program.
|
||
|
||
There are two legal forms for each Assembler control, the full
|
||
form and the abbreviated form. The two forms can be used inter-
|
||
changeable in the source program.
|
||
|
||
Below is a description of each Assembler control. Assembler
|
||
controls with common functionality are grouped together.
|
||
|
||
|
||
6.2. Assembler Control Descriptions
|
||
|
||
|
||
$DATE(date)
|
||
Places the ASCII string enclosed by parenthesis in the date
|
||
field of the page header. The ASCII string can be from 0 to 9
|
||
characters long.
|
||
CONTROL: $DATE(date)
|
||
ABBREV: $DA(date)
|
||
TYPE: Primary
|
||
DEFAULT: No date in page header
|
||
EXAMPLES: $DATE(1-JUL-84)
|
||
$DA(7/22/84)
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
6-1
|
||
|
||
|
||
|
||
|
||
$DEBUG(file)
|
||
$NODEBUG
|
||
These controls determine whether or not a MetaLink Absolute
|
||
Object Module format file is created. The MetaLink Absolute
|
||
Object Module format file is used in conjunction with
|
||
MetaLink's MetaICE series of in-circuit-emulators. Among
|
||
other advantages, it provides powerful symbolic debug
|
||
capability in the emulator debug environment. $NODEBUG
|
||
specifies that a MetaLink Absolute Object Module file will not
|
||
be created. $DEBUG specifies that a MetaLink Absolute Object
|
||
Module file will be created. The $DEBUG control allows any
|
||
legal file name to be specified as the MetaLink Absolute
|
||
Object Module filename. If no filename is specified, a
|
||
default name is used. The default name used for the file is
|
||
the source file name root with a .DBG extension. If the
|
||
$DEBUG control is used, both a MetaLink Absolute Object Module
|
||
file and a standard Intel Hexadecimal format object file can
|
||
be generated at the same time. Refer to the $OBJECT control
|
||
description later in this chapter for information on
|
||
controlling the Hexadecimal format object file output.
|
||
CONTROL: $DEBUG(file)
|
||
$NODEBUG
|
||
ABBREV: $DB(file)
|
||
$NODB
|
||
DEFAULT: $NODEBUG
|
||
TYPE: Primary
|
||
EXAMPLES: $DB(A:NEWNAME.ICE)
|
||
$DEBUG
|
||
$NOOBJECT
|
||
|
||
|
||
$EJECT
|
||
Places a form feed (ASCII 0CH) in the listing output. The
|
||
$NOPAGING control will override this control.
|
||
CONTROL: $EJECT
|
||
ABBREV: $EJ
|
||
DEFAULT: No form feeds in listing output
|
||
TYPE: General
|
||
EXAMPLES: $EJECT
|
||
$EJ
|
||
|
||
|
||
$INCLUDE(file)
|
||
Inserts a file in source program as part of the input source
|
||
program. The file field in this control can be any legal file
|
||
designator. No extension is assumed, so the whole file name
|
||
must be specified. Any number of files can be included in a
|
||
source program. Includes can be nested up to 8 level deep. It
|
||
is important to note that this control inserts files, it does
|
||
not chain or concatenate files.
|
||
CONTROL: $INCLUDE(file)
|
||
ABBREV: $IC(file)
|
||
DEFAULT: No file included in source program
|
||
TYPE: General
|
||
EXAMPLES: $INCLUDE(B:COMMON.EQU
|
||
$IC(TABLES.ASM) ;Uses default drive
|
||
|
||
|
||
6-2
|
||
|
||
|
||
|
||
|
||
$LIST
|
||
$NOLIST
|
||
These controls determine whether or not the source program
|
||
listing is output or not. $LIST will allow the source program
|
||
listing to be output. $NOLIST stops the source program
|
||
listing from being output. The $NOPRINT control overrides the
|
||
$LIST control.
|
||
CONTROL: $LIST
|
||
$NOLIST
|
||
ABBREV: $LI
|
||
$NOLI
|
||
DEFAULT: $LIST
|
||
TYPE: General
|
||
EXAMPLES: $NOLIST ;This will cause the included
|
||
$INCLUDE(COMMON.TBL) ;file not to be listed
|
||
$LI ;Listing continues
|
||
|
||
|
||
$MOD51
|
||
$MOD52
|
||
$MOD44
|
||
$MOD515
|
||
$MOD512
|
||
$MOD517
|
||
$MOD152
|
||
$MOD451
|
||
$MOD452
|
||
$MOD751
|
||
$MOD752
|
||
$MOD154
|
||
$MOD252
|
||
$MOD521
|
||
$MOD552
|
||
$MOD652
|
||
$MOD851
|
||
$NOMOD
|
||
Recognizes predefined special function register symbols in the
|
||
source program. This saves the user from having to define all
|
||
the registers in the source program. Appendix B lists the
|
||
symbols that are defined by these controls. $NOMOD disables
|
||
the recognizing function. These controls access a files of
|
||
the same name that are included with the MetaLink 8051 CROSS
|
||
ASSEMBLER distribution diskette. When a $MOD control is used
|
||
in a source program, it is important that the $MOD file be
|
||
available to the Cross Assembler. The Cross Assembler first
|
||
looks for the $MOD file on the default drive, if it isn't
|
||
found there, the Cross Assembler looks for it on the A: drive.
|
||
The components supported by each switch are:
|
||
$MOD51: 8051, 8751, 8031, 80C51, 80C31, 87C51, 9761, 8053
|
||
$MOD52: 8052, 8032, 8752
|
||
$MOD44: 8044, 8344, 8744
|
||
$MOD515: 80515, 80535, 80C515, 80C535
|
||
$MOD512: 80512, 80532
|
||
$MOD517: 80C517, 80C537
|
||
|
||
|
||
6-3
|
||
|
||
|
||
|
||
|
||
$MOD152: 80C152, 83C152, 80C157
|
||
$MOD451: 80C451. 83C451, 87C451
|
||
$MOD452: 80C452, 83C452, 87C452
|
||
$MOD752: 83C752, 87C752
|
||
$MOD751: 83C751, 87C751
|
||
$MOD154: 83C514, 80C154, 85C154
|
||
$MOD252: 80C252, 83C252, 87C252, 80C51FA, 83C51FA, 87C51FA,
|
||
83C51FB, 87C51FB
|
||
$MOD521: 80C521, 80C321, 87C521, 80C541, 87C541
|
||
$MOD552: 80C552, 83C552, 87C552
|
||
$MOD652: 80C652, 83C652
|
||
$MOD851: 80C851, 83C851
|
||
CONTROL: $MOD51
|
||
$MOD52
|
||
$MOD44
|
||
$MOD152
|
||
$MOD515
|
||
$MOD512
|
||
$MOD451
|
||
$MOD452
|
||
$MOD751
|
||
$MOD752
|
||
$MOD154
|
||
$MOD252
|
||
$MOD521
|
||
$MOD552
|
||
$MOD652
|
||
$MOD517
|
||
$MOD851
|
||
$NOMOD
|
||
|
||
ABBREV:
|
||
DEFAULT: $NOMOD
|
||
TYPE: Primary
|
||
EXAMPLES: $MOD51
|
||
$MOD52
|
||
$MOD44
|
||
$MOD515
|
||
$MOD512
|
||
$MOD152
|
||
$MOD451
|
||
$MOD452
|
||
$MOD751
|
||
$MOD752
|
||
$MOD154
|
||
$MOD252
|
||
$MOD521
|
||
$MOD552
|
||
$MOD652
|
||
$MOD517
|
||
$MOD851
|
||
$NOMOD
|
||
|
||
|
||
$OBJECT(file)
|
||
$NOOBJECT
|
||
|
||
|
||
6-4
|
||
|
||
|
||
|
||
|
||
These controls determine whether or not a standard Intel
|
||
Hexadecimal format object file is created. $NOOBJECT
|
||
specifies that an object file will not be created. $OBJECT
|
||
specifies that an object file will be created. If other than
|
||
the default name is to be used for the object file, the
|
||
$OBJECT control allows any legal file name to be specified as
|
||
the object filename. The default name used for the object
|
||
file is the source file name root with a .HEX extension.
|
||
CONTROL: $OBJECT(file)
|
||
$NOOBJECT
|
||
ABBREV: $OJ(file)
|
||
$NOOJ
|
||
DEFAULT: $OBJECT(source.HEX)
|
||
TYPE: Primary
|
||
EXAMPLES: $OJ(A:NEWNAME.OBJ)
|
||
$NOOBJECT
|
||
|
||
|
||
$PAGING
|
||
$NOPAGING
|
||
These controls specify whether or not the output listing will
|
||
be broken into pages or will be output as one continuous
|
||
listing. When the $NOPAGING control is used, the $EJECT and
|
||
$PAGELENGTH controls are ignored. With the $PAGING control, a
|
||
form feed and header line is inserted into the output listing
|
||
whenever an $EJECT control is met, or whenever the number of
|
||
lines output on the current page exceeds the value specified
|
||
by the $PAGELENGTH control. The header line contains source
|
||
file name, title (if $TITLE control was used), date (if $DATE
|
||
control was used) and page number.
|
||
CONTROL: $PAGING
|
||
$NOPAGING
|
||
ABBREV: $PI
|
||
$NOPI
|
||
DEFAULT: $PAGING
|
||
TYPE: Primary
|
||
EXAMPLES: $PAGING
|
||
$NOPI
|
||
|
||
|
||
|
||
$PAGELENGTH(n)
|
||
Sets the maximum number of lines, (n), on a page of the output
|
||
listing. If the maximum is exceeded, a form feed and page
|
||
header is inserted in the output listing. This control allows
|
||
the number of lines per page to be set anywhere between 10 and
|
||
255. If the number of lines specified is less than 10,
|
||
pagelength will be set to 10. If the number of lines
|
||
specified is greater than 255, pagelength will be set to 255.
|
||
|
||
The $NOPAGING control will override this control.
|
||
CONTROL: $PAGELENGTH(n)
|
||
ABBREV: $PL(n)
|
||
DEFAULT: $PAGELENGTH(60)
|
||
TYPE: Primary
|
||
EXAMPLES: $PAGELENGTH(48)
|
||
|
||
|
||
6-5
|
||
|
||
|
||
|
||
|
||
|
||
$PL(58)
|
||
|
||
|
||
|
||
$PAGEWIDTH(n)
|
||
Sets the maximum number of characters, (n), on a line of the
|
||
output listing. This control allows the number of characters
|
||
per line to be set anywhere between 72 and 132. If the number
|
||
specified is less than 72, the pagewidth is set at 72. If the
|
||
number specified is greater than 132, the pagewidth is set at
|
||
132. If the pagewidth is specified between 72 and 100 and the
|
||
line being output exceeds the pagewidth specification, the
|
||
line is truncated at the specified pagewidth and a carriage
|
||
return/line feed pair is inserted in the listing. If the
|
||
pagewidth is specified to be greater than 100 and the line
|
||
being output exceed the pagewidth specification, a carriage
|
||
return/line feed pair is inserted at the specified pagewidth
|
||
and the line will continue to be listed on the next line
|
||
beginning at column 80.
|
||
CONTROL: $PAGEWIDTH(n)
|
||
ABBREV: $PW(n)
|
||
DEFAULT $PAGEWIDTH(72)
|
||
TYPE: Primary
|
||
EXAMPLES: $PAGEWIDTH(132)
|
||
$PW(80)
|
||
|
||
|
||
|
||
$PRINT(file)
|
||
$NOPRINT
|
||
These controls determine whether or not a listing file is
|
||
created. $NOPRINT specifies that a listing file will not be
|
||
created. $PRINT specifies that an listing file will be
|
||
created. If other than the default name is to be used for the
|
||
listing file, the $PRINT control allows any legal file name to
|
||
be specified as the listing filename. The default name used
|
||
for the listing file is the source file name root with a .LST
|
||
extension.
|
||
|
||
CONTROL: $PRINT(file)
|
||
$NOPRINT
|
||
ABBREV: $PR
|
||
$NOPR
|
||
DEFAULT: $PRINT(source.LST)
|
||
TYPE: Primary
|
||
EXAMPLES: $PRINT(A:CONTROL.OUT)
|
||
$NOPR
|
||
|
||
|
||
$SYMBOLS
|
||
$NOSYMBOLS
|
||
Selects whether or not the symbol table is appended to the
|
||
listing output. $SYMBOLS causes the symbol table to be sorted
|
||
alphabetically by symbol, formatted and output to the listing
|
||
file. Along with the symbol name, its value and type are
|
||
output. Values are output in hexadecimal. Types include NUMB
|
||
|
||
|
||
6-6
|
||
|
||
|
||
|
||
|
||
(number), ADDR (address), REG (register symbol) and ACC
|
||
(accumulator symbol). If a symbol was of type ADDR, it
|
||
segment is also output as either C (code), D (data) or X
|
||
(external). Other information listed with the symbols is NOT
|
||
USED (symbol defined but never referenced), UNDEFINED (symbol
|
||
referenced but never defined) and REDEFINEABLE (symbol defined
|
||
using the SET directive). The type and value listed for a
|
||
REDEFINABLE symbol is that of its last definition in the
|
||
source program. $NOSYMBOLS does not output the symbol table.
|
||
CONTROL: $SYMBOLS
|
||
$NOSYMBOLS
|
||
ABBREV: $SB
|
||
$NOSB
|
||
DEFAULT: $SYMBOLS
|
||
TYPE: Primary
|
||
EXAMPLES: $SB
|
||
$NOSYMBOLS
|
||
|
||
|
||
$TITLE(string)
|
||
Places the ASCII string enclosed by the parenthesis in the
|
||
title field of the page header. The ASCII string can be from
|
||
0 to 64 characters long. If the string is greater than 64
|
||
characters or if the width of the page will not support such a
|
||
long title, the title will be truncated. If parentheses are
|
||
part of the string, they must be balanced.
|
||
CONTROL: $TITLE(string)
|
||
ABBREV: $TT(string)
|
||
DEFAULT: No title in page header
|
||
TYPE: Primary
|
||
EXAMPLES: $TITLE(SAMPLE PROGRAM V1.2)
|
||
$TT(METALINK (TM) CROSS ASSEMBLER)
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
6-7
|
||
|
||
|
||
|
||
|
||
|
||
|
||
CHAPTER 7
|
||
|
||
|
||
8051 CROSS ASSEMBLER MACRO PROCESSOR
|
||
|
||
|
||
7.1. Introduction
|
||
|
||
Macros are useful for code that is used repetitively throughout
|
||
the program. It saves the programmer the time and tedium of
|
||
having to specify the code every time it is used. The code is
|
||
written only once in the macro definition and it can be used
|
||
anywhere in the source program any number of times by simply
|
||
using the macro name.
|
||
|
||
Sometimes there is confusion between macros and subroutines.
|
||
Subroutines are common routines that are written once by the
|
||
programmer and then accessed by CALLing them. Subroutines are
|
||
usually used for longer and more complex routines where the
|
||
call/return overhead can be tolerated. Macros are commonly used
|
||
for simpler routines or where the speed of in-line code is
|
||
required.
|
||
|
||
|
||
7.2. Macro Definition
|
||
|
||
Before a macro can be used, it first must be defined. The macro
|
||
definition specifies a template that is inserted into the source
|
||
program whenever the macro name is encountered. Macro
|
||
definitions can not be nested, but once a macro is defined, it
|
||
can be used in other macro definitions. Macros used this way can
|
||
be nested up to nine levels deep.
|
||
|
||
The macro definition has three parts to it: 1) the macro header
|
||
which specifies the macro name and its parameter list, 2) the
|
||
macro body which is the part that is actually inserted into the
|
||
source program, and 3) the macro terminator.
|
||
|
||
The macro header has the following form:
|
||
|
||
name MACRO <parameter list>
|
||
|
||
The name field contains a unique symbol that it used to identify
|
||
the macro. Whenever that symbol is encountered in the source
|
||
program, the Cross Assembler will automatically insert the macro
|
||
body in the source program at that point. The name must be a
|
||
unique symbol that follows all the rules of symbol formation as
|
||
outlined in Chapter 2.
|
||
|
||
The MACRO field of the macro header contains the keyword MACRO.
|
||
This is used to notify the Cross Assembler that this is the
|
||
beginning of a macro definition.
|
||
|
||
|
||
|
||
7-1
|
||
|
||
|
||
|
||
|
||
The <parameter list> field of the macro header lists anywhere
|
||
from zero to 16 parameters that are used in the macro body and
|
||
are defined at assembly time. The symbols used in the parameter
|
||
list are only used by the Cross Assembler during the storing of
|
||
the macro definition. As a result, while symbols used in the
|
||
parameter list must be unique symbols that follow all the the
|
||
rules of symbol formation as outlined in Chapter 2, they can be
|
||
reissued in the parameter list of another macro definition
|
||
without conflict. Parameter list items are separated from one
|
||
another by a comma. The following are examples of macro
|
||
definition headers:
|
||
|
||
MULT_BY_16 MACRO (no parameters)
|
||
DIRECT_ADD MACRO DESTINATION,SOURCE (two parameters)
|
||
|
||
The macro body contains the template that will replace the macro
|
||
name in the source program. The macro body can contain
|
||
instructions, directives, conditional assembly statements or
|
||
controls. As a matter of fact, the macro body can contain any
|
||
legal Cross Assembler construct as defined in Chapters 2, 4, 5
|
||
and 6.
|
||
|
||
There are two macro definition terminators: ENDM and EXITM.
|
||
Every macro definition must have an ENDM at the end of its
|
||
definition to notify the Cross Assembler that the macro
|
||
definition is complete. The EXITM terminator is an alternative
|
||
ending of the macro that is useful with conditional assembly
|
||
statements. When a EXITM is encountered in a program, all
|
||
remaining statements (to the ENDM) are ignored.
|
||
|
||
The following is an example of a macro definition that multiplies
|
||
the Accumulator by 16:
|
||
|
||
MULT_BY_16 MACRO
|
||
RL A ;* 2
|
||
RL A ;* 4
|
||
RL A ;* 8
|
||
RL A ;* 16
|
||
ENDM
|
||
|
||
The following is an example of a macro that adds two numbers
|
||
together. This could be used by the programmer to do direct
|
||
memory to memory adds of external variables (create a virtual
|
||
instruction).
|
||
|
||
|
||
DIRECT_ADDX MACRO DESTINATION,SOURCE (two parameters)
|
||
MOV R0,#SOURCE
|
||
MOVX A,@R0
|
||
MOV R1,A
|
||
MOV R0,#DESTINATION
|
||
MOVX A,@R0
|
||
ADD A,R1
|
||
MOVX @R0,A
|
||
ENDM
|
||
|
||
|
||
|
||
7-2
|
||
|
||
|
||
|
||
|
||
A final macro definition example shows the use of the EXITM
|
||
macro terminator. If CMOS is non-zero, the MOV and only the MOV
|
||
instruction will be translated by the Cross Assembler.
|
||
|
||
IDLE MACRO
|
||
IF (CMOS)
|
||
MOV PCON,#IDL
|
||
EXITM
|
||
ENDIF
|
||
JMP $
|
||
ENDM
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
7-3
|
||
|
||
|
||
|
||
|
||
7.3. Special Macro Operators
|
||
|
||
There are four special macro operators that are defined below:
|
||
|
||
% when the PERCENT sign prefaces a symbol in the
|
||
parameter list, the symbol's value is passed to
|
||
the macro's body instead of the symbol itself.
|
||
|
||
! when the EXCLAMATION POINT precedes a character,
|
||
that character is handled as a literal and is
|
||
passed to the macro body with the EXCLAMATION
|
||
POINT removed. This is useful when it is
|
||
necessary to pass a delimiter to the macro body.
|
||
For example, in the following parameter list, the
|
||
second parameter passed to the macro body would be
|
||
a COMMA ( , ):
|
||
GENERATE_INST 75,!,,STK_VALUE
|
||
|
||
& when the AMPERSAND is used in the macro body, the
|
||
symbols on both sides of it are concatenated
|
||
together and the AMPERSAND is removed.
|
||
|
||
;; when double SEMI-COLONS are used in a macro
|
||
definition, the comment preceded by the double
|
||
SEMI_COLONS will not be saved and thus will not
|
||
appear in the listing whenever the macro is
|
||
invoked. Using the double SEMI-COLONS lowers the
|
||
memory requirement in storing the macro
|
||
definitions and should be used whenever possible.
|
||
|
||
Examples of using the above special macro operators follow in the
|
||
"Using Macros" section.
|
||
|
||
|
||
7.4. Using Macros
|
||
|
||
This section section discusses several situations that arise
|
||
using macros and how to handle them. In general the discussion
|
||
uses examples to get the point across. First the macro
|
||
definition is listed, then the source line program that will
|
||
invoke the macro and finally how the macro was expanded by the
|
||
Cross Assembler.
|
||
|
||
7.4.1. NESTING MACROS
|
||
|
||
The following shows a macro nested to a depth of three.
|
||
Remember, definitions cannot be nested. Macros must be defined
|
||
before they are used in other macro definitions.
|
||
|
||
;MACRO DEFINITIONS
|
||
|
||
GET_EXT_BYTE MACRO EXT_ADDR
|
||
MOV R0,#EXT_ADDR
|
||
MOVX A,@R0
|
||
ENDM
|
||
|
||
|
||
|
||
7-4
|
||
|
||
|
||
|
||
|
||
ADD_EXT_BYTES MACRO EXT_DEST,EXT_SRC
|
||
GET_EXT_BYTE EXT_DEST
|
||
MOV R1,A
|
||
GET_EXT_BYTE EXT_SRC
|
||
ADD A,R1
|
||
ENDM
|
||
|
||
ADD_DIRECT_BYTES MACRO DESTINATION,SOURCE
|
||
IF (SMALL_MODEL)
|
||
MOV A,SOURCE
|
||
ADD A,DESTINATION
|
||
MOV DESTINATION
|
||
ELSE
|
||
ADD_EXT_BYTES DESTINATION,SOURCE
|
||
MOVX @R0,A
|
||
ENDIF
|
||
ENDM
|
||
|
||
|
||
;USAGE IN PROGRAM
|
||
|
||
ADD_DIRECT_BYTES 127,128
|
||
|
||
;TRANSLATED MACRO
|
||
|
||
|
||
30 +1 ADD_DIRECT_BYTES 127,128
|
||
31 +1 IF (SMALL_MODEL)
|
||
32 +1 MOV A,128
|
||
33 +1 ADD A,127
|
||
34 +1 MOV 127
|
||
35 +1 ELSE
|
||
36 +2 ADD_EXT_BYTES 127,128
|
||
37 +3 GET_EXT_BYTE 127
|
||
0100 787F 38 +3 MOV R0,#127
|
||
0102 E2 39 +3 MOVX A,@R0
|
||
0103 F9 40 +2 MOV R1,A
|
||
41 +3 GET_EXT_BYTE 128
|
||
0104 7880 42 +3 MOV R0,#128
|
||
0106 E2 43 +3 MOVX A,@R0
|
||
0107 29 44 +2 ADD A,R1
|
||
0108 F2 45 +1 MOVX @R0,A
|
||
46 +1 ENDIF
|
||
48
|
||
|
||
Two things should be pointed out from the above example. First,
|
||
the order of the parameter list is important. You must maintain
|
||
the the order of parameters from the macro definition if the
|
||
Cross Assembler is to translate the macro correctly.
|
||
|
||
Secondly, in order to pass parameters to nested macros, simply
|
||
use the same parameter symbol in the parameter list of the
|
||
definition. For example, the parameter DESTINATION was passed
|
||
properly to the nested macros ADD_EXT_BYTES and GET_EXT_BYTE.
|
||
This occurred because in the macro definition of
|
||
ADD_DIRECT_BYTES, the parameter DESTINATION was specified in the
|
||
|
||
|
||
7-5
|
||
|
||
|
||
|
||
|
||
parameter lists of both ADD_EXT_BYTES and GET_EXT_BYTE.
|
||
|
||
|
||
7.4.2. LABELS IN MACROS
|
||
|
||
You have two choices for specifying labels in a macro body. A
|
||
label can either be passed to the body as a parameter or it can
|
||
be generated within the body. The following example shows both
|
||
ways.
|
||
|
||
|
||
;MACRO DEFINITION
|
||
|
||
MULTIPLE_SHIFT MACRO LABEL,LABEL_SUFFIX,COUNTER,N
|
||
COUNTER SET COUNTER+1 ;INCREMENT SUFFIX FOR NEXT
|
||
USAGE
|
||
|
||
LABEL: MOV R0,#N
|
||
SHIFT&LABEL_SUFFIX: RL A
|
||
DJNZ R0,SHIFT&LABEL_SUFFIX
|
||
ENDM
|
||
|
||
|
||
;USAGE IN PROGRAM
|
||
|
||
MULTIPLE_SHIFT LOOP_SHIFT,%COUNT,COUNT,4
|
||
|
||
|
||
;TRANSLATED MACRO
|
||
|
||
15 +1 MULTIPLE_SHIFT LOOP_SHIFT,%COUNT,COUNT,4
|
||
0006 16 +1 COUNT SET COUNT+1
|
||
17 +1
|
||
0100 7804 18 +1 LOOP_SHIFT: MOV R0,#4
|
||
0102 23 19 +1 SHIFT5: RL A
|
||
0103 D8FD 20 +1 DJNZ R0,SHIFT5
|
||
22
|
||
|
||
Points to note in the above example: 1) the double semi-colon
|
||
caused the comment not to be listed in the translated macro; 2)
|
||
the percent sign caused the value of COUNT (in this case the
|
||
value 5) to be passed to the macro body instead of the symbol;
|
||
and 3) the ampersand allowed two symbols to be concatenated to
|
||
form the label SHIFT5.
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
7-6
|
||
|
||
|
||
|
||
|
||
CHAPTER 8
|
||
|
||
|
||
8051 CROSS ASSEMBLER ERROR CODES
|
||
|
||
|
||
8.1. Introduction
|
||
|
||
When the Cross Assembler encounters an error in the source
|
||
program, it will emit an error message in the listing file. If
|
||
the $NOPRINT control has been invoked, the error message will be
|
||
output to the screen.
|
||
|
||
There are basically two types of errors that are encountered by
|
||
the Cross Assembler, translation errors and I/O errors. I/O
|
||
errors are usually fatal errors. However, whenever an error is
|
||
detected, the Cross Assembler makes every effort possible to
|
||
continue with the assembly.
|
||
|
||
If it is possible to recover from the error and continue
|
||
assembling, the Cross Assembler will report the error, use a
|
||
default condition and continue on its way. However, when a fatal
|
||
error is encountered, it is impossible for the Cross Assembler to
|
||
proceed. In this case, the Cross Assembler reports the error and
|
||
then aborts the assembly process.
|
||
|
||
Fatal I/O error messages are displayed on the screen and are of
|
||
the form:
|
||
|
||
FATAL ERROR opening <filename>
|
||
|
||
where <filename> would be replaced with the file designator
|
||
initially entered or read from the source program. The cause of
|
||
this error is usually obvious, typically a typographical error or
|
||
the wrong drive specification.
|
||
|
||
Another fatal I/O error message is:
|
||
|
||
FATAL ERROR writing to <type> file
|
||
|
||
where <type> would be replaced with either "listing" or "object".
|
||
The cause of this error is usually either a write protected disk
|
||
or a full disk.
|
||
|
||
Translation error reports contain at least three lines. The
|
||
first line is the source line in which the error was detected,
|
||
the second line is a pointer to the character, symbol, expression
|
||
or line that caused the error. The final line is the error
|
||
message itself. There may be more than one error message,
|
||
depending on the number of errors in the source line. An example
|
||
of a source line with two errors in it follows:
|
||
|
||
0100 2323 26 START: MOV AB,@35
|
||
|
||
|
||
8-1
|
||
|
||
|
||
|
||
****----------------------------------------^---^
|
||
****ERROR #20: Illegal operand
|
||
****ERROR #20: Illegal operand
|
||
|
||
The errors are pointed out by the up-arrows ( ^ ). For every up-
|
||
arrow there will be an error message. Errors are ordered left to
|
||
right, so the first error message corresponds to the left-most
|
||
up-arrow and so on. The error message includes an error number
|
||
and an description of the error. The error number can be used as
|
||
an index to the more detailed error explanations that follow in
|
||
this chapter.
|
||
|
||
After the Cross Assembler has completed its translation process,
|
||
it will print an assembly complete message:
|
||
|
||
ASSEMBLY COMPLETE, nn ERRORS FOUND
|
||
|
||
If it was an error free assembly, in place of the "nn" above the
|
||
word "NO" will be output. However, if errors were encountered
|
||
during the assembly process, the "nn" will be replaced with the
|
||
number of errors that were found (up to a maximum of 50). In this
|
||
case, an error summary will follow in the listing file with all
|
||
the errors that were reported during the assembly. An error
|
||
summary looks like the following:
|
||
|
||
ERROR SUMMARY:
|
||
Line #26, ERROR #20: Illegal operand
|
||
Line #26, ERROR #20: Illegal operand
|
||
|
||
The same error message that occurred after the source line
|
||
appears again prefaced by the source line number to aid in
|
||
tracking down the error in the source listing.
|
||
|
||
|
||
8.2. Explanation of Error Messages
|
||
|
||
ERROR #1: Illegal character
|
||
This error occurs when the Cross Assembler encounters a
|
||
character that is not part of its legal character set. The
|
||
Cross Assembler character set can be found in Appendix D.
|
||
|
||
ERROR #2: Undefined symbol
|
||
This error occurs when the Cross Assembler tries to use a
|
||
symbol that hasn't been defined. The two most common reasons
|
||
for this error are typographical errors and forward
|
||
references.
|
||
|
||
ERROR #3: Duplicate symbol
|
||
This error occurs when a previously defined symbol or a
|
||
reserved symbol is attempted to be defined again. Refer to
|
||
Appendix C for the reserved words. Also inspect the symbol in
|
||
the symbol table listing. If the symbol doesn't appear there,
|
||
you are using a reserved word. If the symbol does appear, its
|
||
original definition will be listed.
|
||
|
||
ERROR #4: Illegal digit for radix
|
||
A digit was encountered that is not part of the legal digits
|
||
|
||
|
||
8-2
|
||
|
||
|
||
|
||
|
||
for the radix specified. Chapter 2 lists the legal digits for
|
||
each radix available. Often this error occurs because a
|
||
symbol was started with a number instead of a letter, question
|
||
mark, or underscore.
|
||
|
||
ERROR #5: Number too large
|
||
The number specified, or the returned value of the expression,
|
||
exceeds 16-bit precision. The largest value allowed is
|
||
65,535.
|
||
|
||
ERROR #6: Missing END directive
|
||
The source program must end with one and only one END
|
||
directive. The END is placed after all the assembly line
|
||
statements.
|
||
|
||
ERROR #7: Illegal opcode/directive after label
|
||
The symbol after a label is not an opcode nor a directive that
|
||
allows labels. The only thing permitted on a line after a
|
||
label is an instruction, the DS, DB or DW directives, or a
|
||
comment. If none of these are found, this error will be
|
||
reported.
|
||
|
||
ERROR #8: Illegal assembly line
|
||
The assembly line doesn't begin with a symbol, label,
|
||
instruction mnemonic, control, directive, comment or null
|
||
line. No attempt is made to translate such a line.
|
||
|
||
ERROR #9: Text beyond END directive
|
||
The END directive must be the last line of the source program.
|
||
Any text beyond the END line will cause this error. Any such
|
||
text is ignore. Text here is defined as any printable ASCII
|
||
characters.
|
||
|
||
ERROR #10: Illegal or missing expression
|
||
A number, symbol or arithmetic expression was expected, but it
|
||
was either found to be missing or the Cross Assembler was
|
||
unable to evaluate it properly.
|
||
|
||
ERROR #11: Illegal or missing expression operator
|
||
An arithmetic operator was expected but it is either missing
|
||
or it is not one of the legal operators specified in Chapter
|
||
2.
|
||
|
||
ERROR #12: Unbalanced parentheses
|
||
In evaluating an expression, the parentheses in the expression
|
||
were found not to balance.
|
||
|
||
ERROR #13: Illegal or missing expression value
|
||
In evaluating an expression, the Cross Assembler expected to
|
||
find either a number or a symbol, but it was either missing or
|
||
illegal.
|
||
|
||
ERROR #14: Illegal literal expression
|
||
This error occurs when a null ASCII literal string is found.
|
||
A null ASCII literal is nothing more than two apostrophes
|
||
together ( '' ) and is illegal.
|
||
|
||
|
||
8-3
|
||
|
||
|
||
|
||
|
||
ERROR #15: Expression stack overflow
|
||
The expression stack has a depth of 32 values. The expression
|
||
being evaluated exceeds this depth. This is a very rare
|
||
error. However, if you ever get it, divide the expression
|
||
into two or more expressions using the EQU directive.
|
||
|
||
ERROR #16: Division by zero
|
||
The expression being evaluated includes an attempt to divide
|
||
by zero.
|
||
|
||
ERROR #17: Illegal bit designator
|
||
A bit designator address was specified in the source program
|
||
and it points to an illegal bit address. A bit designator
|
||
contains a byte address, followed by a PERIOD, followed by the
|
||
bit index into the byte address (e.g., ACC.7) as discussed in
|
||
Chapter 2. This error can occur for one of two reasons.
|
||
First, if the number or a symbol that is used to specify the
|
||
byte address part of the bit designator is not a legal bit
|
||
addressable address, ERROR #17 will occur. Second, if the bit
|
||
index into the byte address exceeds the number 7, again ERROR
|
||
#17 will be output.
|
||
|
||
ERROR #18: Target address exceeds relative address range
|
||
A Program Counter relative jump instruction (e.g., SJMP, JZ,
|
||
JNC, etc.) was decoded with the target address of the jump
|
||
exceeding the maximum possible forward jump of 127 bytes or
|
||
the maximum possible backward jump of 128 bytes.
|
||
|
||
ERROR #20: Illegal operand
|
||
The operand specified is not a legal operand for the
|
||
instruction. Review the legal operands allowed for the
|
||
instruction.
|
||
|
||
ERROR #21: Illegal indirect register
|
||
R0 and R1 are the only primary legal indirect register. This
|
||
error occurs when the indirect addressing mode designator (@)
|
||
is not followed by either R0, R1 or symbols that were defined
|
||
to be equivalent to either R0 or R1. This error can also
|
||
occur in the MOVC A,@A+DPTR, MOVC A,@A+PC, MOVX A,@DPTR, MOVX
|
||
@DPTR,A and the JMP @A+DPTR instructions if the operands after
|
||
the indirect addressing mode designator ( @ ) aren't specified
|
||
properly.
|
||
|
||
ERROR #22: Missing operand delimiter
|
||
A COMMA operand delimiter is missing from the operand fields
|
||
of the instruction.
|
||
|
||
ERROR #23: Illegal or missing directive
|
||
This error occurs when the Cross Assembler cannot find a legal
|
||
directive. The most common cause of this error is due to
|
||
leaving the COLON off a label. As a result, the following
|
||
opcode mnemonic is attempted to be decoded as a directive.
|
||
|
||
ERROR #24: Attempting to EQUate a previously SET symbol
|
||
Once a symbol is defined using the SET directive, it cannot be
|
||
|
||
|
||
8-4
|
||
|
||
|
||
|
||
|
||
later redefined using the EQU directive.
|
||
|
||
ERROR #25: Attempting to SET a previously EQUated symbol
|
||
Once a symbol is defined using the EQU directive, it cannot be
|
||
redefined. If you want the symbol to be redefineable, use the
|
||
SET directive.
|
||
|
||
ERROR #26: Illegal SET/EQU expression
|
||
The expression following the SET or EQU directive is illegal.
|
||
This typically occurs when an attempt is made to define a
|
||
symbol to be equivalent to an implicit register other than A,
|
||
R0, R1, R2, R3, R4, R5, R6 or R7.
|
||
|
||
ERROR #27: Illegal expression with forward reference
|
||
This error occurs when an expression contains a symbol that
|
||
hasn't been defined yet. Move the symbol definition earlier
|
||
in the source file.
|
||
|
||
ERROR #28: Address exceeds segment range
|
||
The address specified exceeds 255 and you are in the DSEG,
|
||
BSEG, or ISEG.
|
||
|
||
ERROR #29: Expecting an EOL or COMMENT
|
||
The Cross Assembler has completed processing a legal assembly
|
||
language line and expected the line to be terminated with
|
||
either a COMMENT or a carriage return/line feed pair.
|
||
|
||
ERROR #30: Illegal directive with current active segment
|
||
The specified directive is not legal in the active segment.
|
||
This can happen by trying to use the DBIT directive in other
|
||
than the BSEG, or using the DS directive in the BSEG.
|
||
|
||
ERROR #31: Only two character string allowed
|
||
This error occurs using the DW directive. The maximum ASCII
|
||
literal allowed in a DW specification is a two character
|
||
string.
|
||
|
||
ERROR #32: Byte definition exceeds 255
|
||
This error occurs using the DB directive. The value specified
|
||
in the DB specification cannot fit into a byte.
|
||
|
||
ERROR #33: Premature end of string
|
||
An ASCII literal string was not terminated properly with an
|
||
apostrophe.
|
||
|
||
ERROR #34: Illegal register bank number
|
||
This error occurs when the number specified with the USING
|
||
directive exceed 3. Legal register bank numbers are: 0, 1, 2,
|
||
3.
|
||
|
||
ERROR #35: Include file nesting exceeds 8
|
||
The maximum number of nested include files is eight. You will
|
||
get this error if you exceed this limit.
|
||
|
||
ERROR #36: Illegal or missing argument
|
||
This error occurs when the syntax of a Cross Assembler control
|
||
|
||
|
||
8-5
|
||
|
||
|
||
|
||
|
||
requires an argument and it was either incorrectly specified
|
||
or is missing all together.
|
||
|
||
ERROR #37: Illegal control statement
|
||
The Cross Assembler does not recognize the specified control.
|
||
The legal controls are detailed in Chapter 6.
|
||
|
||
ERROR #38: Unable to open file
|
||
The Cross Assembler is unable to open the file as specified.
|
||
This is a fatal error which will abort the assembly process.
|
||
|
||
ERROR #39: Illegal file specification
|
||
The file specification is not a legal file designator. Refer
|
||
to your DOS manual for a description of legal file
|
||
designators. This is a fatal error which will abort the
|
||
assembly process.
|
||
|
||
ERROR #40: Program synchronization error
|
||
This error occurs when the Cross Assembler is generating the
|
||
object hex file and finds that the code segment location
|
||
counter is not advancing properly. There are two cases where
|
||
this can happen. First, if the source program uses ORG
|
||
directives and they are not placed in ascending order. Second,
|
||
if a generic CALL or JMP is made to a forward reference that
|
||
is actually defined later in the program to be a backward
|
||
reference. For example, the following code sequence will cause
|
||
this error due to the second reason:
|
||
|
||
BACK_REF: NOP
|
||
CALL FORWARD_REF
|
||
FORWARD_REF EQU BACK_REF
|
||
|
||
During the first pass, the generic CALL will be replaced with
|
||
a 3-byte LCALL instruction. During the second pass, the
|
||
generic CALL will be replaced with a 2-byte ACALL instruction.
|
||
To prevent this kind of problem, use the generic CALLs and
|
||
JMPs with labeled targets, not EQU or SET defined symbols.
|
||
|
||
ERROR #41: Insufficient memory
|
||
This error occurs when there isn't enough memory to hold all
|
||
the symbols that have been generated by the source program.
|
||
If you have 96 Kbytes or more of RAM this will be a very rare
|
||
error. Only a massive source program or numerous large macros
|
||
could potentially cause this error. However, if this error
|
||
does occur, your best bet is to either buy more memory or to
|
||
break up your program into smaller pieces and share common
|
||
symbols with a common $INCLUDE file.
|
||
|
||
ERROR #42: More errors detected, not listed
|
||
The internal error buffer can hold 50 errors. If more than 50
|
||
errors occur, only the first 50 will be reported.
|
||
|
||
ERROR #43: ENDIF without IF
|
||
The terminator of a conditional assembly block (ENDIF) was
|
||
recognized without seeing a matching IF.
|
||
|
||
|
||
|
||
8-6
|
||
|
||
|
||
|
||
|
||
ERROR #44: Missing ENDIF
|
||
A conditional assembly block was begun with an IF statement,
|
||
but no matching ENDIF was detected.
|
||
|
||
ERROR #45: Illegal or missing macro name
|
||
The MACRO keyword was recognized, but the symbol that is
|
||
supposed to precede the MACRO keyword was missing, an illegal
|
||
symbol or a duplicate symbol.
|
||
|
||
ERROR #46: Macro nesting too deep
|
||
Macros can be nested to a depth of 9 levels. Exceeding this
|
||
limit will cause this error.
|
||
|
||
ERROR #47: Number of parameters doesn't match definition
|
||
In attempting to use a macro, the number of parameters in the
|
||
parameter list does not equal the number of parameters
|
||
specified in the macro definition. They must match.
|
||
|
||
ERROR #48: Illegal parameter specification
|
||
This error typically occurs when a previously defined symbol
|
||
is used in the parameter list of the macro definition.
|
||
|
||
ERROR #49: Too many parameters
|
||
The maximum number of parameters in a macro parameter list is
|
||
sixteen. This error occurs when you exceed that limit.
|
||
|
||
ERROR #50: Line exceeds 255 characters
|
||
The maximum length of a source line is 255 characters. If a
|
||
carriage return/line feed pair is not detected in the first
|
||
256 characters of a line, this error is reported and the line
|
||
is truncated at 255 characters.
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
8-7
|
||
|
||
|
||
|
||
|
||
|
||
|
||
APPENDIX A
|
||
|
||
|
||
SAMPLE PROGRAM AND LISTING
|
||
|
||
|
||
|
||
A.1. Source File
|
||
|
||
|
||
;
|
||
; 8-bit by 8-bit signed multiply--byte signed multiply
|
||
;
|
||
; This routine takes the signed byte in multiplicand and
|
||
; multiplies it by the signed byte in multiplier and places
|
||
; the signed 16-bit product in product_high and product_low.
|
||
;
|
||
; This routine assumes 2s complement representation of signed
|
||
; numbers. The maximum numbers possible are then -128 and
|
||
; +127. Multiplying the possible maximum numbers together
|
||
; easily fits into a 16-bit product, so no overflow test is
|
||
; done on the answer.
|
||
;
|
||
; Registers altered by routine: A, B, PSW.
|
||
;
|
||
;
|
||
; Primary controls
|
||
$MOD51
|
||
$TITLE(BYTE SIGNED MULTIPLY)
|
||
$DATE(JUL-30-84)
|
||
$PAGEWIDTH(132)
|
||
$OBJECT(B:BMULB.OBJ)
|
||
;
|
||
;
|
||
; Variable declarations
|
||
;
|
||
sign_flag BIT 0F0H ;sign of product
|
||
multiplier DATA 030H ;8-bit multiplier
|
||
multiplicand DATA 031H ;8-bit multiplicand
|
||
product_high DATA 032H ;high byte of 16-bit answer
|
||
product_low DATA 033H ;low byte of answer
|
||
;
|
||
;
|
||
;
|
||
ORG 100H ;arbitrary start
|
||
;
|
||
byte_signed_multiply:
|
||
CLR sign_flag ;reset sign
|
||
MOV A,multiplier ;put multiplier in accumulator
|
||
JNB ACC.7,positive ;test sign bit of multiplier
|
||
CPL A ;negative--complement and
|
||
INC A ;add 1 to convert to positive
|
||
SETB sign_flag ;and set sign flag
|
||
;
|
||
|
||
|
||
A-1
|
||
|
||
|
||
|
||
|
||
positive: MOV B,multiplicand ;put multiplicand in B register
|
||
JNB B.7,multiply ;test sign bit of multiplicand
|
||
XRL B,#0FFh ;negative--complement and
|
||
INC B ;add 1 to convert to positive
|
||
CPL sign_flag ;complement sign flag
|
||
;
|
||
multiply: MUL AB ;do unsigned multiplication
|
||
;
|
||
sign_test: JNB sign_flag,byte_signed_exit ;if positive,done
|
||
XRL B,#0FFh ;else have to complement both
|
||
CPL A ;bytes of the product and inc
|
||
ADD A,#1 ;add here because inc doesn't
|
||
JNC byte_signed_exit ;set the carry flag
|
||
INC B ;if add overflowed A, inc the
|
||
;high byte
|
||
byte_signed_exit:
|
||
MOV product_high,B ;save the answer
|
||
MOV product_low,A
|
||
;
|
||
RET ;and return
|
||
END
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
A-2
|
||
|
||
|
||
|
||
|
||
A.2. Source File Listing
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
A-3
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
A-4
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
A-5
|
||
|
||
|
||
|
||
|
||
|
||
APPENDIX B
|
||
|
||
PRE-DEFINED BYTE AND BIT ADDRESSES
|
||
|
||
The following tables detail the pre-defined byte and bit addresses
|
||
for the 8051/8031 microcontrollers supported by the MetaLink family
|
||
of emulators. Proliferation parts are delimited from the standard
|
||
MCS-51 definitions by asterisk ("*") boxes.
|
||
|
||
This list covers these microcontrollers:
|
||
|
||
8044 8031 8032 8051 8052 8053 80C154 80C321
|
||
8344 80C31 80C32 8751 8752 8753 83C154 80C521
|
||
8744 80C51 80C52 85C154 87C521
|
||
87C51
|
||
|
||
80C321 80C51FA(80C252) 80C452 80C152JA/JB/JC/JD 80C851
|
||
80C541 83C51FA(83C252) 83C452 83C152JA/JC 83C851
|
||
87C541 87C51FA(87C252) 87C452
|
||
|
||
80C451 80C652 80C552 83C751 83C752 80512 80515 80C515 80C517
|
||
83C451 83C652 83C552 87C751 87C752 80532 80535 80C535 80C537
|
||
87C451 87C652 87C552
|
||
|
||
B.1. Pre-defined Byte Addresses
|
||
|
||
P0 DATA 080H ;PORT 0
|
||
SP DATA 081H ;STACK POINTER
|
||
DPL DATA 082H ;DATA POINTER - LOW BYTE
|
||
DPH DATA 083H ;DATA POINTER - HIGH BYTE
|
||
|
||
************************************************************************
|
||
for the 80C321/80C521
|
||
DPL1 DATA 084H ;DATA POINTER LOW 1
|
||
DPH1 DATA 085H ;DATA POINTER HIGH 1
|
||
DPS DATA 086H ;DATA POINTER SELECTION
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 83C152/80C152
|
||
GMOD DATA 084H ;GSC MODE
|
||
TFIFO DATA 085H ;GSC TRANSMIT BUFFER
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C517/80C537
|
||
WDTREL DATA 086H ;WATCHDOG TIMER RELOAD REG
|
||
************************************************************************
|
||
|
||
PCON DATA 087H ;POWER CONTROL
|
||
TCON DATA 088H ;TIMER CONTROL
|
||
TMOD DATA 089H ;TIMER MODE
|
||
TL0 DATA 08AH ;TIMER 0 - LOW BYTE
|
||
TL1 DATA 08BH ;TIMER 1 - LOW BYTE
|
||
|
||
|
||
B-1
|
||
|
||
|
||
|
||
|
||
************************************************************************
|
||
for the 83C751/83C752
|
||
RTL DATA 08BH ;TIMER 0 - LOW BYTE RELOAD
|
||
************************************************************************
|
||
|
||
TH0 DATA 08CH ;TIMER 0 - HIGH BYTE
|
||
TH1 DATA 08DH ;TIMER 1 - HIGH BYTE
|
||
|
||
************************************************************************
|
||
for the 83C751/83C752
|
||
RTH DATA 08DH ;TIMER 0 - HIGH BYTE RELOAD
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 83C752
|
||
PWM DATA 08EH ;PULSE WIDTH MODULATION
|
||
************************************************************************
|
||
|
||
P1 DATA 090H ;PORT 1
|
||
|
||
************************************************************************
|
||
for the 83C152/80C152
|
||
P5 DATA 091H ;PORT 5
|
||
DCON0 DATA 092H ;DMA CONTROL 0
|
||
DCON1 DATA 093H ;DMA CONTROL 1
|
||
BAUD DATA 094H ;GSC BAUD RATE
|
||
ADR0 DATA 095H ;GSC MATCH ADDRESS 0
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C452/83C452
|
||
DCON0 DATA 092H ;DMA CONTROL 0
|
||
DCON1 DATA 093H ;DMA CONTROL 1
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C517/80C537
|
||
DPSEL DATA 092H ;DATA POINTER SELECT REGISTER
|
||
************************************************************************
|
||
|
||
SCON DATA 098H ;SERIAL PORT CONTROL
|
||
SBUF DATA 099H ;SERIAL PORT BUFFER
|
||
|
||
************************************************************************
|
||
for the 83C751/83C752
|
||
I2CON DATA 098H ;I2C CONTROL
|
||
I2DAT DATA 099H ;I2C DATA
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C517/80C537
|
||
IEN2 DATA 09AH ;INTERRUPT ENABLE REGISTER 2
|
||
S1CON DATA 09BH ;SERIAL PORT CONTROL 1
|
||
S1BUF DATA 09CH ;SERIAL PORT BUFFER 1
|
||
S1REL DATA 09DH ;SERIAL RELOAD REG 1
|
||
************************************************************************
|
||
|
||
P2 DATA 0A0H ;PORT 2
|
||
IE DATA 0A8H ;INTERRUPT ENABLE
|
||
|
||
|
||
|
||
B-2
|
||
|
||
|
||
|
||
|
||
************************************************************************
|
||
for the 80C51FA/83C51FA(83C252/80C252)
|
||
SADDR DATA 0A9H ;SLAVE INDIVIDUAL ADDRESS
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80515/80535 and 80C517/80C537
|
||
IP0 DATA 0A9H ;INTERRUPT PRIORITY REGISTER 0
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C321/80C521
|
||
WDS DATA 0A9H ;WATCHDOG SELECTION
|
||
WDK DATA 0AAH ;WATCHDOG KEY
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 83C152/80C152
|
||
P6 DATA 0A1H ;PORT 6
|
||
SARL0 DATA 0A2H ;DMA SOURCE ADDR. 0 (LOW)
|
||
SARH0 DATA 0A3H ;DMA SOURCE ADDR. 0 (HIGH)
|
||
IFS DATA 0A4H ;GSC INTERFRAME SPACING
|
||
ADR1 DATA 0A5H ;GSC MATCH ADDRESS 1
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C452/83C452
|
||
SARL0 DATA 0A2H ;DMA SOURCE ADDR. 0 (LOW)
|
||
SARH0 DATA 0A3H ;DMA SOURCE ADDR. 0 (HIGH)
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C552/83C552
|
||
CML0 DATA 0A9H ;COMPARE 0 - LOW BYTE
|
||
CML1 DATA 0AAH ;COMPARE 1 - LOW BYTE
|
||
CML2 DATA 0ABH ;COMPARE 2 - LOW BYTE
|
||
CTL0 DATA 0ACH ;CAPTURE 0 - LOW BYTE
|
||
CTL1 DATA 0ADH ;CAPTURE 1 - LOW BYTE
|
||
CTL2 DATA 0AEH ;CAPTURE 2 - LOW BYTE
|
||
CTL3 DATA 0AFH ;CAPTURE 3 - LOW BYTE
|
||
************************************************************************
|
||
|
||
P3 DATA 0B0H ;PORT 3
|
||
|
||
************************************************************************
|
||
for the 83C152/80C152
|
||
SARL1 DATA 0B2H ;DMA SOURCE ADDR. 1 (LOW)
|
||
SARH1 DATA 0B3H ;DMA SOURCE ADDR. 1 (HIGH)
|
||
SLOTTM DATA 0B4H ;GSC SLOT TIME
|
||
ADR2 DATA 0B5H ;GSC MATCH ADDRESS 2
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C452/83C452
|
||
SARL1 DATA 0B2H ;DMA SOURCE ADDR. 1 (LOW)
|
||
SARH1 DATA 0B3H ;DMA SOURCE ADDR. 1 (HIGH)
|
||
************************************************************************
|
||
|
||
IP DATA 0B8H ;INTERRUPT PRIORITY
|
||
|
||
************************************************************************
|
||
for the 80C51FA/83C51FA(83C252/80C252)
|
||
|
||
|
||
B-3
|
||
|
||
|
||
|
||
|
||
SADEN DATA 0B9H ;SLAVE ADDRESS ENABLE
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80515/80535 and 80C517/80C537
|
||
IP1 DATA 0B9H ;INTERRUPT PRIORITY REGISTER 1
|
||
IRCON DATA 0C0H ;INTERRUPT REQUEST CONTROL
|
||
CCEN DATA 0C1H ;COMPARE/CAPTURE ENABLE
|
||
CCL1 DATA 0C2H ;COMPARE/CAPTURE REGISTER 1 - LOW BYTE
|
||
CCH1 DATA 0C3H ;COMPARE/CAPTURE REGISTER 1 - HIGH BYTE
|
||
CCL2 DATA 0C4H ;COMPARE/CAPTURE REGISTER 2 - LOW BYTE
|
||
CCH2 DATA 0C5H ;COMPARE/CAPTURE REGISTER 2 - HIGH BYTE
|
||
CCL3 DATA 0C6H ;COMPARE/CAPTURE REGISTER 3 - LOW BYTE
|
||
CCH3 DATA 0C7H ;COMPARE/CAPTURE REGISTER 3 - HIGH BYTE
|
||
T2CON DATA 0C8H ;TIMER 2 CONTROL
|
||
CRCL DATA 0CAH ;COMPARE/RELOAD/CAPTURE - LOW BYTE
|
||
CRCH DATA 0CBH ;COMPARE/RELOAD/CAPTURE - HIGH BYTE
|
||
TL2 DATA 0CCH ;TIMER 2 - LOW BYTE
|
||
TH2 DATA 0CDH ;TIMER 2 - HIGH BYTE
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C517/80C537
|
||
CC4EN DATA 0C9H ;COMPARE/CAPTURE 4 ENABLE
|
||
CCL4 DATA 0CEH ;COMPARE/CAPTURE REGISTER 4 - LOW BYTE
|
||
CCH4 DATA 0CFH ;COMPARE/CAPTURE REGISTER 4 - HIGH BYTE
|
||
************************************************************************
|
||
************************************************************************
|
||
for the RUPI-44
|
||
STS DATA 0C8H ;SIU STATUS REGISTER
|
||
SMD DATA 0C9H ;SERIAL MODE
|
||
RCB DATA 0CAH ;RECEIVE CONTROL BYTE
|
||
RBL DATA 0CBH ;RECEIVE BUFFER LENGTH
|
||
RBS DATA 0CCH ;RECEIVE BUFFER START
|
||
RFL DATA 0CDH ;RECEIVE FIELD LENGTH
|
||
STAD DATA 0CEH ;STATION ADDRESS
|
||
DMA_CNT DATA 0CFH ;DMA COUNT
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 8052/8032, 80C51FA/83C51FA(83C252/80C252), 80C154/83C154
|
||
T2CON DATA 0C8H ;TIMER 2 CONTROL
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C51FA/83C51FA(83C252/80C252)
|
||
T2MOD DATA 0C9H ;TIMER 2 MODE CONTROL
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 8052/8032, 80C51FA/83C51FA(83C252/80C252), 80C154/83C154
|
||
RCAP2L DATA 0CAH ;TIMER 2 CAPTURE REGISTER, LOW BYTE
|
||
RCAP2H DATA 0CBH ;TIMER 2 CAPTURE REGISTER, HIGH BYTE
|
||
TL2 DATA 0CCH ;TIMER 2 - LOW BYTE
|
||
TH2 DATA 0CDH ;TIMER 2 - HIGH BYTE
|
||
************************************************************************
|
||
|
||
|
||
|
||
|
||
|
||
|
||
B-4
|
||
|
||
|
||
|
||
************************************************************************
|
||
for the 83C152/80C152
|
||
P4 DATA 0C0H ;PORT 4
|
||
DARL0 DATA 0C2H ;DMA DESTINATION ADDR. 0 (LOW)
|
||
DARH0 DATA 0C3H ;DMA DESTINATION ADDR. 0 (HIGH)
|
||
BKOFF DATA 0C4H ;GSC BACKOFF TIMER
|
||
ADR3 DATA 0C5H ;GSC MATCH ADDRESS 3
|
||
IEN1 DATA 0C8H ;INTERRUPT ENABLE REGISTER 1
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C452/83C452
|
||
P4 DATA 0C0H ;PORT 4
|
||
DARL0 DATA 0C2H ;DMA DESTINATION ADDR. 0 (LOW)
|
||
DARH0 DATA 0C3H ;DMA DESTINATION ADDR. 0 (HIGH)
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C451/83C451
|
||
P4 DATA 0C0H ;PORT 4
|
||
P5 DATA 0C8H ;PORT 5
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80512/80532
|
||
IRCON DATA 0C0H ;INTERRUPT REQUEST CONTROL
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C552/83C552
|
||
P4 DATA 0C0H ;PORT 4
|
||
P5 DATA 0C4H ;PORT 5
|
||
ADCON DATA 0C5H ;A/D CONVERTER CONTROL
|
||
ADCH DATA 0C6H ;A/D CONVERTER HIGH BYTE
|
||
TM2IR DATA 0C8H ;T2 INTERRUPT FLAGS
|
||
CMH0 DATA 0C9H ;COMPARE 0 - HIGH BYTE
|
||
CMH1 DATA 0CAH ;COMPARE 1 - HIGH BYTE
|
||
CMH2 DATA 0CBH ;COMPARE 2 - HIGH BYTE
|
||
CTH0 DATA 0CCH ;CAPTURE 0 - HIGH BYTE
|
||
CTH1 DATA 0CDH ;CAPTURE 1 - HIGH BYTE
|
||
CTH2 DATA 0CEH ;CAPTURE 2 - HIGH BYTE
|
||
CTH3 DATA 0CFH ;CAPTURE 3 - HIGH BYTE
|
||
************************************************************************
|
||
|
||
PSW DATA 0D0H ;PROGRAM STATUS WORD
|
||
|
||
************************************************************************
|
||
for the RUPI-44
|
||
NSNR DATA 0D8H ;SEND COUNT/RECEIVE COUNT
|
||
SIUST DATA 0D9H ;SIU STATE COUNTER
|
||
TCB DATA 0DAH ;TRANSMIT CONTROL BYTE
|
||
TBL DATA 0DBH ;TRANSMIT BUFFER LENGTH
|
||
TBS DATA 0DCH ;TRANSMIT BUFFER START
|
||
FIFO0 DATA 0DDH ;THREE BYTE FIFO
|
||
FIFO1 DATA 0DEH
|
||
FIFO2 DATA 0DFH
|
||
************************************************************************
|
||
|
||
|
||
|
||
|
||
B-5
|
||
|
||
|
||
|
||
************************************************************************
|
||
for the 80C51FA/83C51FA(83C252/80C252)
|
||
CCON DATA 0D8H ;CONTROL COUNTER
|
||
CMOD DATA 0D9H ;COUNTER MODE
|
||
CCAPM0 DATA 0DAH ;COMPARE/CAPTURE MODE FOR PCA MODULE 0
|
||
CCAPM1 DATA 0DBH ;COMPARE/CAPTURE MODE FOR PCA MODULE 1
|
||
CCAPM2 DATA 0DCH ;COMPARE/CAPTURE MODE FOR PCA MODULE 2
|
||
CCAPM3 DATA 0DDH ;COMPARE/CAPTURE MODE FOR PCA MODULE 3
|
||
CCAPM4 DATA 0DEH ;COMPARE/CAPTURE MODE FOR PCA MODULE 4
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80515/80535
|
||
ADCON DATA 0D8H ;A/D CONVERTER CONTROL
|
||
ADDAT DATA 0D9H ;A/D CONVERTER DATA
|
||
DAPR DATA 0DAH ;D/A CONVERTER PROGRAM REGISTER
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 83C152/80C152
|
||
DARL1 DATA 0D2H ;DMA DESTINATION ADDR. 1 (LOW)
|
||
DARH1 DATA 0D3H ;DMA DESTINATION ADDR. 1 (HIGH)
|
||
TCDCNT DATA 0D4H ;GSC TRANSMIT COLLISION COUNTER
|
||
AMSK0 DATA 0D5H ;GSC ADDRESS MASK 0
|
||
TSTAT DATA 0D8H ;TRANSMIT STATUS (DMA & GSC)
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C452/83C452
|
||
DARL1 DATA 0D2H ;DMA DESTINATION ADDR. 1 (LOW)
|
||
DARH1 DATA 0D3H ;DMA DESTINATION ADDR. 1 (HIGH)
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C451/83C451
|
||
P6 DATA 0D8H ;PORT 6
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80512/80532
|
||
ADCON DATA 0D8H ;A/D CONVERTER CONTROL
|
||
ADDAT DATA 0D9H ;A/D CONVERTER DATA
|
||
DAPR DATA 0DAH ;D/A CONVERTER PROGRAM REGISTER
|
||
P6 DATA 0DBH ;PORT 6
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 83C751/83C752
|
||
I2CFG DATA 0D8H ;I2C CONFIGURATION
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C552/83C552 and 80C652/83C652
|
||
S1CON DATA 0D8H ;SERIAL 1 CONTROL
|
||
S1STA DATA 0D9H ;SERIAL 1 STATUS
|
||
S1DAT DATA 0DAH ;SERIAL 1 DATA
|
||
S1ADR DATA 0DBH ;SERIAL 1 SLAVE ADDRESS
|
||
************************************************************************
|
||
|
||
|
||
|
||
|
||
|
||
B-6
|
||
|
||
|
||
|
||
************************************************************************
|
||
for the 80C517/80C537
|
||
CML0 DATA 0D2H ;COMPARE REGISTER 0 - LOW BYTE
|
||
CMH0 DATA 0D3H ;COMPARE REGISTER 0 - HIGH BYTE
|
||
CML1 DATA 0D4H ;COMPARE REGISTER 1 - LOW BYTE
|
||
CMH1 DATA 0D5H ;COMPARE REGISTER 1 - HIGH BYTE
|
||
CML2 DATA 0D6H ;COMPARE REGISTER 2 - LOW BYTE
|
||
CMH2 DATA 0D7H ;COMPARE REGISTER 2 - HIGH BYTE
|
||
ADCON0 DATA 0D8H ;A/D CONVERTER CONTROL 0
|
||
ADDAT DATA 0D9H ;A/D CONVERTER DATA
|
||
DAPR DATA 0DAH ;D/A CONVERTER PROGRAM REGISTER
|
||
P7 DATA 0DBH ;PORT 7
|
||
ADCON1 DATA 0DCH ;A/D CONVERTER CONTROL 1
|
||
P8 DATA 0DDH ;PORT 8
|
||
CTRELL DATA 0DEH ;COM TIMER REL REG - LOW BYTE
|
||
CTRELH DATA 0DFH ;COM TIMER REL REG - HIGH BYTE
|
||
************************************************************************
|
||
|
||
ACC DATA 0E0H ;ACCUMULATOR
|
||
|
||
************************************************************************
|
||
for the 83C152/80C152
|
||
BCRL0 DATA 0E2H ;DMA BYTE COUNT 0 (LOW)
|
||
BCRH0 DATA 0E3H ;DMA BYTE COUNT 0 (HIGH)
|
||
PRBS DATA 0E4H ;GSC PSEUDO-RANDOM SEQUENCE
|
||
AMSK1 DATA 0E5H ;GSC ADDRESS MASK 1
|
||
RSTAT DATA 0E8H ;RECEIVE STATUS (DMA & GSC)
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C452/83C452
|
||
BCRL0 DATA 0E2H ;DMA BYTE COUNT 0 (LOW)
|
||
BCRH0 DATA 0E3H ;DMA BYTE COUNT 0 (HIGH)
|
||
HSTAT DATA 0E6H ;HOST STATUS
|
||
HCON DATA 0E7H ;HOST CONTROL
|
||
SLCON DATA 0E8H ;SLAVE CONTROL
|
||
SSTAT DATA 0E9H ;SLAVE STATUS
|
||
IWPR DATA 0EAH ;INPUT WRITE POINTER
|
||
IRPR DATA 0EBH ;INPUT READ POINTER
|
||
CBP DATA 0ECH ;CHANNEL BOUNDARY POINTER
|
||
FIN DATA 0EEH ;FIFO IN
|
||
CIN DATA 0EFH ;COMMAND IN
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80515/80535
|
||
P4 DATA 0E8H ;PORT 4
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C451/83C451
|
||
CSR DATA 0E8H ;CONTROL STATUS
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80512/80532
|
||
P4 DATA 0E8H ;PORT 4
|
||
************************************************************************
|
||
|
||
|
||
|
||
|
||
B-7
|
||
|
||
|
||
|
||
************************************************************************
|
||
for the 80C552/83C552
|
||
IEN1 DATA 0E8H ;INTERRUPT ENABLE REGISTER 1
|
||
TM2CON DATA 0EAH ;T2 COUNTER CONTROL
|
||
CTCON DATA 0EBH ;CAPTURE CONTROL
|
||
TML2 DATA 0ECH ;TIMER 2 - LOW BYTE
|
||
TMH2 DATA 0EDH ;TIMER 2 - HIGH BYTE
|
||
STE DATA 0EEH ;SET ENABLE
|
||
RTE DATA 0EFH ;RESET/TOGGLE ENABLE
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C51FA/83C51FA(83C252/80C252)
|
||
CL DATA 0E9H ;CAPTURE BYTE LOW
|
||
CCAP0L DATA 0EAH ;COMPARE/CAPTURE 0 LOW BYTE
|
||
CCAP1L DATA 0EBH ;COMPARE/CAPTURE 1 LOW BYTE
|
||
CCAP2L DATA 0ECH ;COMPARE/CAPTURE 2 LOW BYTE
|
||
CCAP3L DATA 0EDH ;COMPARE/CAPTURE 3 LOW BYTE
|
||
CCAP4L DATA 0EEH ;COMPARE/CAPTURE 4 LOW BYTE
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C517/80C537
|
||
CTCON DATA 0E1H ;COM TIMER CONTROL REG
|
||
CML3 DATA 0E2H ;COMPARE REGISTER 3 - LOW BYTE
|
||
CMH3 DATA 0E3H ;COMPARE REGISTER 3 - HIGH BYTE
|
||
CML4 DATA 0E4H ;COMPARE REGISTER 4 - LOW BYTE
|
||
CMH4 DATA 0E5H ;COMPARE REGISTER 4 - HIGH BYTE
|
||
CML5 DATA 0E6H ;COMPARE REGISTER 5 - LOW BYTE
|
||
CMH5 DATA 0E7H ;COMPARE REGISTER 5 - HIGH BYTE
|
||
P4 DATA 0E8H ;PORT 4
|
||
MD0 DATA 0E9H ;MUL/DIV REG 0
|
||
MD1 DATA 0EAH ;MUL/DIV REG 1
|
||
MD2 DATA 0EBH ;MUL/DIV REG 2
|
||
MD3 DATA 0ECH ;MUL/DIV REG 3
|
||
MD4 DATA 0EDH ;MUL/DIV REG 4
|
||
MD5 DATA 0EEH ;MUL/DIV REG 5
|
||
ARCON DATA 0EFH ;ARITHMETIC CONTROL REG
|
||
************************************************************************
|
||
|
||
B DATA 0F0H ;MULTIPLICATION REGISTER
|
||
|
||
************************************************************************
|
||
for the 80C154/83C154
|
||
IOCON DATA 0F8H ;I/O CONTROL REGISTER
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 83C152/80C152
|
||
BCRL1 DATA 0F2H ;DMA BYTE COUNT 1 (LOW)
|
||
BCRH1 DATA 0F3H ;DMA BYTE COUNT 1 (HIGH)
|
||
RFIFO DATA 0F4H ;GSC RECEIVE BUFFER
|
||
MYSLOT DATA 0F5H ;GSC SLOT ADDRESS
|
||
IPN1 DATA 0F8H ;INTERRUPT PRIORITY REGISTER 1
|
||
************************************************************************
|
||
|
||
|
||
|
||
|
||
|
||
B-8
|
||
|
||
|
||
|
||
************************************************************************
|
||
for the 83C851/80C851
|
||
EADRL DATA 0F2H ;EEPROM Address Register - Low Byte
|
||
EADRH DATA 0F3H ;EEPROM Address Register - High Byte
|
||
EDAT DATA 0F4H ;EEPROM Data Register
|
||
ETIM DATA 0F5H ;EEPROM Timer Register
|
||
ECNTRL DATA 0F6H ;EEPROM Control Register
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C452/83C452
|
||
BCRL1 DATA 0F2H ;DMA BYTE COUNT 1 (LOW)
|
||
BCRH1 DATA 0F3H ;DMA BYTE COUNT 1 (HIGH)
|
||
ITHR DATA 0F6H ;INPUT FIFO THRESHOLD
|
||
OTHR DATA 0F7H ;OUTPUT FIFO THRESHOLD
|
||
IEP DATA 0F8H ;INTERRUPT PRIORITY
|
||
MODE DATA 0F9H ;MODE
|
||
ORPR DATA 0FAH ;OUTPUT READ POINTER
|
||
OWPR DATA 0FBH ;OUTPUT WRITE POINTER
|
||
IMIN DATA 0FCH ;IMMEDIATE COMMAND IN
|
||
IMOUT DATA 0FDH ;IMMEDIATE COMMAND OUT
|
||
FOUT DATA 0FEH ;FIFO OUT
|
||
COUT DATA 0FFH ;COMMAND OUT
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80515/80535
|
||
P5 DATA 0F8H ;PORT 5
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80512/80532
|
||
P5 DATA 0F8H ;PORT 5
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 83C751/83C752
|
||
I2STA DATA 0F8H ;I2C STATUS
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C552/83C552
|
||
IP1 DATA 0F8H ;INTERRUPT PRIORITY REGISTER 1
|
||
PWM0 DATA 0FCH ;PULSE WIDTH REGISTER 0
|
||
PWM1 DATA 0FDH ;PULSE WIDTH REGISTER 1
|
||
PWMP DATA 0FEH ;PRESCALER FREQUENCY CONTROL
|
||
T3 DATA 0FFH ;T3 - WATCHDOG TIMER
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C517/80C537
|
||
CMEN DATA 0F6H ;COMPARE ENABLE
|
||
CML6 DATA 0F2H ;COMPARE REGISTER 6 - LOW BYTE
|
||
CMH6 DATA 0F3H ;COMPARE REGISTER 6 - HIGH BYTE
|
||
CML7 DATA 0F4H ;COMPARE REGISTER 7 - LOW BYTE
|
||
CMH7 DATA 0F5H ;COMPARE REGISTER 7 - HIGH BYTE
|
||
CMSEL DATA 0F7H ;COMPARE INPUT REGISTER
|
||
P5 DATA 0F8H ;PORT 5
|
||
P6 DATA 0FAH ;PORT 6
|
||
************************************************************************
|
||
|
||
|
||
|
||
B-9
|
||
|
||
|
||
|
||
************************************************************************
|
||
for the 80C51FA/83C51FA(83C252/80C252)
|
||
CH DATA 0F9H ;CAPTURE HIGH BYTE
|
||
CCAP0H DATA 0FAH ;COMPARE/CAPTURE 0 HIGH BYTE
|
||
CCAP1H DATA 0FBH ;COMPARE/CAPTURE 1 HIGH BYTE
|
||
CCAP2H DATA 0FCH ;COMPARE/CAPTURE 2 HIGH BYTE
|
||
CCAP3H DATA 0FDH ;COMPARE/CAPTURE 3 HIGH BYTE
|
||
CCAP4H DATA 0FEH ;COMPARE/CAPTURE 4 HIGH BYTE
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 83C752
|
||
PWENA DATA 0FEH ;PULSE WIDTH ENABLE
|
||
************************************************************************
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
B-10
|
||
|
||
|
||
|
||
B.2. Pre-defined Bit Addresses
|
||
|
||
************************************************************************
|
||
for the 83C751/83C752
|
||
SCL BIT 080H ;P0.0 - I2C SERIAL CLOCK
|
||
SDA BIT 081H ;P0.1 - I2C SERIAL DATA
|
||
************************************************************************
|
||
|
||
IT0 BIT 088H ;TCON.0 - EXT. INTERRUPT 0 TYPE
|
||
IE0 BIT 089H ;TCON.1 - EXT. INTERRUPT 0 EDGE FLAG
|
||
IT1 BIT 08AH ;TCON.2 - EXT. INTERRUPT 1 TYPE
|
||
IE1 BIT 08BH ;TCON.3 - EXT. INTERRUPT 1 EDGE FLAG
|
||
TR0 BIT 08CH ;TCON.4 - TIMER 0 ON/OFF CONTROL
|
||
TF0 BIT 08DH ;TCON.5 - TIMER 0 OVERFLOW FLAG
|
||
TR1 BIT 08EH ;TCON.6 - TIMER 1 ON/OFF CONTROL
|
||
TF1 BIT 08FH ;TCON.7 - TIMER 1 OVERFLOW FLAG
|
||
|
||
************************************************************************
|
||
for the 83C751/83C752
|
||
C/T BIT 08EH ;TCON.6 - COUNTER OR TIMER OPERATION
|
||
GATE BIT 08FH ;TCON.7 - GATE TIMER
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80515/80535
|
||
INT3 BIT 090H ;P1.0 - EXT. INTERRUPT 3/CAPT & COMP 0
|
||
INT4 BIT 091H ;P1.1 - EXT. INTERRUPT 4/CAPT & COMP 1
|
||
INT5 BIT 092H ;P1.2 - EXT. INTERRUPT 5/CAPT & COMP 2
|
||
INT6 BIT 093H ;P1.3 - EXT. INTERRUPT 6/CAPT & COMP 3
|
||
INT2 BIT 094H ;P1.4 - EXT. INTERRUPT 2
|
||
T2EX BIT 095H ;P1.5 - TIMER 2 EXT. RELOAD TRIGGER INP
|
||
CLKOUT BIT 096H ;P1.6 - SYSTEM CLOCK OUTPUT
|
||
T2 BIT 097H ;P1.7 - TIMER 2 INPUT
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 83C152/80C152
|
||
GRXD BIT 090H ;P1.0 - GSC RECEIVER DATA INPUT
|
||
GTXD BIT 091H ;P1.1 - GSC TRANSMITTER DATA OUTPUT
|
||
DEN BIT 092H ;P1.2 - DRIVE ENABLE TO ENABLE EXT DRIVE
|
||
TXC BIT 093H ;P1.3 - GSC EXTERNAL TRANSMIT CLOCK INPU
|
||
RXC BIT 094H ;P1.4 - GSC EXTERNAL RECEIVER CLOCK INPU
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 83C552/80C552
|
||
CT0I BIT 090H ;P1.0 - CAPTURE/TIMER INPUT 0
|
||
CT1I BIT 091H ;P1.1 - CAPTURE/TIMER INPUT 1
|
||
CT2I BIT 092H ;P1.2 - CAPTURE/TIMER INPUT 2
|
||
CT3I BIT 093H ;P1.3 - CAPTURE/TIMER INPUT 3
|
||
T2 BIT 094H ;P1.4 - T2 EVENT INPUT
|
||
RT2 BIT 095H ;P1.5 - T2 TIMER RESET SIGNAL
|
||
SCL BIT 096H ;P1.6 - SERIAL PORT CLOCK LINE I2C
|
||
SDA BIT 097H ;P1.7 - SERIAL PORT DATA LINE I2C
|
||
************************************************************************
|
||
|
||
|
||
|
||
|
||
|
||
B-11
|
||
|
||
|
||
|
||
************************************************************************
|
||
for the 80C517/80C537
|
||
INT3 BIT 090H ;P1.0 - EXT. INTERRUPT 3/CAPT & COMP 0
|
||
INT4 BIT 091H ;P1.1 - EXT. INTERRUPT 4/CAPT & COMP 1
|
||
INT5 BIT 092H ;P1.2 - EXT. INTERRUPT 5/CAPT & COMP 2
|
||
INT6 BIT 093H ;P1.3 - EXT. INTERRUPT 6/CAPT & COMP 3
|
||
INT2 BIT 094H ;P1.4 - EXT. INTERRUPT 2
|
||
T2EX BIT 095H ;P1.5 - TIMER 2 EXT. RELOAD TRIGGER INPU
|
||
CLKOUT BIT 096H ;P1.6 - SYSTEM CLOCK OUTPUT
|
||
T2 BIT 097H ;P1.7 - TIMER 2 INPUT
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C452/83C452 and 80C152/83C152
|
||
HLD BIT 095H ;P1.5 - DMA HOLD REQUEST I/O
|
||
HLDA BIT 096H ;P1.6 - DMA HOLD ACKNOWLEDGE OUTPUT
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 83C751/83C752
|
||
INT0 BIT 095H ;P1.5 - EXTERNAL INTERRUPT 0 INPUT
|
||
INT1 BIT 096H ;P1.6 - EXTERNAL INTERRUPT 1 INPUT
|
||
T0 BIT 096H ;P1.7 - TIMER 0 COUNT INPUT
|
||
************************************************************************
|
||
|
||
RI BIT 098H ;SCON.0 - RECEIVE INTERRUPT FLAG
|
||
TI BIT 099H ;SCON.1 - TRANSMIT INTERRUPT FLAG
|
||
RB8 BIT 09AH ;SCON.2 - RECEIVE BIT 8
|
||
TB8 BIT 09BH ;SCON.3 - TRANSMIT BIT 8
|
||
REN BIT 09CH ;SCON.4 - RECEIVE ENABLE
|
||
SM2 BIT 09DH ;SCON.5 - SERIAL MODE CONTROL BIT 2
|
||
SM1 BIT 09EH ;SCON.6 - SERIAL MODE CONTROL BIT 1
|
||
SM0 BIT 09FH ;SCON.7 - SERIAL MODE CONTROL BIT 0
|
||
|
||
************************************************************************
|
||
for the 83C751/83C752
|
||
MASTER BIT(READ) 099H ;I2CON.1 - MASTER
|
||
STP BIT(READ) 09AH ;I2CON.2 - STOP
|
||
STR BIT(READ) 09BH ;I2CON.3 - START
|
||
ARL BIT(READ) 09CH ;I2CON.4 - ARBITRATION LOSS
|
||
DRDY BIT(READ) 09DH ;I2CON.5 - DATA READY
|
||
ATN BIT(READ) 09EH ;I2CON.6 - ATTENTION
|
||
RDAT BIT(READ) 09FH ;I2CON.7 - RECEIVE DATA
|
||
XSTP BIT(WRITE)098H ;I2CON.0 - TRANSMIT STOP
|
||
XSTR BIT(WRITE)099H ;I2CON.1 - TRANSMIT REPEATED START
|
||
CSTP BIT(WRITE)09AH ;I2CON.2 - CLEAR STOP
|
||
CSTR BIT(WRITE)09BH ;I2CON.3 - CLEAR START
|
||
CARL BIT(WRITE)09CH ;I2CON.4 - CLEAR ARBITRATION LOSS
|
||
CDR BIT(WRITE)09DH ;I2CON.5 - CLEAR DATA READY
|
||
IDLE BIT(WRITE)09EH ;I2CON.6 - GO IDLE
|
||
CXA BIT(WRITE)09FH ;I2CON.7 - CLEAR TRANSMIT ACTIVE
|
||
************************************************************************
|
||
|
||
EX0 BIT 0A8H ;IE.0 - EXTERNAL INTERRUPT 0 ENABLE
|
||
ET0 BIT 0A9H ;IE.1 - TIMER 0 INTERRUPT ENABLE
|
||
EX1 BIT 0AAH ;IE.2 - EXTERNAL INTERRUPT 1 ENABLE
|
||
ET1 BIT 0ABH ;IE.3 - TIMER 1 INTERRUPT ENABLE
|
||
ES BIT 0ACH ;IE.4 - SERIAL PORT INTERRUPT ENABLE
|
||
|
||
|
||
B-12
|
||
|
||
|
||
|
||
************************************************************************
|
||
for the 83C751/83C752
|
||
EI2 BIT 0ACH ;IE.4 - SERIAL PORT INTERRUPT ENABLE
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 8052/8032, 80C154/83C154, 80C252(80C51FA), 80515/80535
|
||
ET2 BIT 0ADH ;TIMER 2 INTERRUPT ENABLE
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C652/83C652
|
||
ES1 BIT 0ADH ;IE.5 - SERIAL PORT 1 INTERRUPT ENABLE
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C252(80C51FA)
|
||
EC BIT 0AEH ;IE.6 - ENABLE PCA INTERRUPT
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80515/80535
|
||
WDT BIT 0AEH ;IEN0.6 - WATCHDOG TIMER RESET
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 83C552/80C552
|
||
ES1 BIT 0ADH ;IEN0.5 - SERIAL PORT 1 INTERRUPT ENABLE
|
||
EAD BIT 0AEH ;IEN0.6 - ENABLE A/D INTERRUPT
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C517/80C537
|
||
ET2 BIT 0ADH ;IEN0.5 - TIMER 2 INTERRUPT ENABLE
|
||
WDT BIT 0AEH ;IEN0.6 - WATCHDOG TIMER RESET
|
||
************************************************************************
|
||
|
||
EA BIT 0AFH ;IE.7 - GLOBAL INTERRUPT ENABLE
|
||
RXD BIT 0B0H ;P3.0 - SERIAL PORT RECEIVE INPUT
|
||
TXD BIT 0B1H ;P3.1 - SERIAL PORT TRANSMIT OUTPUT
|
||
INT0 BIT 0B2H ;P3.2 - EXTERNAL INTERRUPT 0 INPUT
|
||
INT1 BIT 0B3H ;P3.3 - EXTERNAL INTERRUPT 1 INPUT
|
||
T0 BIT 0B4H ;P3.4 - TIMER 0 COUNT INPUT
|
||
T1 BIT 0B5H ;P3.5 - TIMER 1 COUNT INPUT
|
||
WR BIT 0B6H ;P3.6 - WRITE CONTROL FOR EXT. MEMORY
|
||
RD BIT 0B7H ;P3.7 - READ CONTROL FOR EXT. MEMORY
|
||
PX0 BIT 0B8H ;IP.0 - EXTERNAL INTERRUPT 0 PRIORITY
|
||
PT0 BIT 0B9H ;IP.1 - TIMER 0 PRIORITY
|
||
PX1 BIT 0BAH ;IP.2 - EXTERNAL INTERRUPT 1 PRIORITY
|
||
PT1 BIT 0BBH ;IP.3 - TIMER 1 PRIORITY
|
||
PS BIT 0BCH ;IP.4 - SERIAL PORT PRIORITY
|
||
|
||
************************************************************************
|
||
for the 80C154/83C154
|
||
PT2 BIT 0BCH ;IP.5 - TIMER 2 PRIORITY
|
||
PCT BIT 0BFH ;IP.7 - INTERRUPT PRIORITY DISABLE
|
||
************************************************************************
|
||
|
||
|
||
|
||
|
||
|
||
B-13
|
||
|
||
|
||
|
||
************************************************************************
|
||
for the 80C652/83C652
|
||
PS1 BIT 0BDH ;IP.5 - SERIAL PORT 1 PRIORITY
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C51FA/83C51FA(83C252/80C252)
|
||
PT2 BIT 0BDH ;IP.5 - TIMER 2 PRIORITY
|
||
PPC BIT 0BEH ;IP.6 - PCA PRIORITY
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80515/80535 and 80C517/80C537
|
||
EADC BIT 0B8H ;IEN1.0 - A/D CONVERTER INTERRUPT EN
|
||
EX2 BIT 0B9H ;IEN1.1 - EXT. INTERRUPT 2 ENABLE
|
||
EX3 BIT 0BAH ;IEN1.2 - EXT. INT 3/CAPT/COMP INT 0 EN
|
||
EX4 BIT 0BBH ;IEN1.3 - EXT. INT 4/CAPT/COMP INT 1 EN
|
||
EX5 BIT 0BCH ;IEN1.4 - EXT. INT 5/CAPT/COMP INT 2 EN
|
||
EX6 BIT 0BDH ;IEN1.5 - EXT. INT 6/CAPT/COMP INT 3 EN
|
||
SWDT BIT 0BEH ;IEN1.6 - WATCHDOG TIMER START
|
||
EXEN2 BIT 0BFH ;IEN1.7 - T2 EXT. RELOAD INTER START
|
||
IADC BIT 0C0H ;IRCON.0 - A/D CONVERTER INTER REQUEST
|
||
IEX2 BIT 0C1H ;IRCON.1 - EXT. INTERRUPT 2 EDGE FLAG
|
||
IEX3 BIT 0C2H ;IRCON.2 - EXT. INTERRUPT 3 EDGE FLAG
|
||
IEX4 BIT 0C3H ;IRCON.3 - EXT. INTERRUPT 4 EDGE FLAG
|
||
IEX5 BIT 0C4H ;IRCON.4 - EXT. INTERRUPT 5 EDGE FLAG
|
||
IEX6 BIT 0C5H ;IRCON.5 - EXT. INTERRUPT 6 EDGE FLAG
|
||
TF2 BIT 0C6H ;IRCON.6 - TIMER 2 OVERFLOW FLAG
|
||
EXF2 BIT 0C7H ;IRCON.7 - TIMER 2 EXT. RELOAD FLAG
|
||
T2IO BIT 0C8H ;T2CON.0 - TIMER 2 INPUT SELECT BIT 0
|
||
T2I1 BIT 0C9H ;T2CON.1 - TIMER 2 INPUT SELECT BIT 1
|
||
T2CM BIT 0CAH ;T2CON.2 - COMPARE MODE
|
||
T2R0 BIT 0CBH ;T2CON.3 - TIMER 2 RELOAD MODE SEL BIT 0
|
||
T2R1 BIT 0CCH ;T2CON.4 - TIMER 2 RELOAD MODE SEL BIT 1
|
||
I2FR BIT 0CDH ;T2CON.5 - EXT. INT 2 F/R EDGE FLAG
|
||
I3FR BIT 0CEH ;T2CON.6 - EXT. INT 3 F/R EDGE FLAG
|
||
T2PS BIT 0CFH ;T2CON.7 - PRESCALER SELECT BIT
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 83C552/80C552
|
||
PS1 BIT 0BDH ;IP0.5 - SIO1
|
||
PAD BIT 0BEH ;IP0.6 - A/D CONVERTER
|
||
CMSR0 BIT 0C0H ;P4.0 - T2 COMPARE AND SET/RESET OUTPUTS
|
||
CMSR1 BIT 0C1H ;P4.1 - T2 COMPARE AND SET/RESET OUTPUTS
|
||
CMSR2 BIT 0C2H ;P4.2 - T2 COMPARE AND SET/RESET OUTPUTS
|
||
CMSR3 BIT 0C3H ;P4.3 - T2 COMPARE AND SET/RESET OUTPUTS
|
||
CMSR4 BIT 0C4H ;P4.4 - T2 COMPARE AND SET/RESET OUTPUTS
|
||
CMSR5 BIT 0C5H ;P4.5 - T2 COMPARE AND SET/RESET OUTPUTS
|
||
CMT0 BIT 0C6H ;P4.6 - T2 COMPARE AND TOGGLE OUTPUTS
|
||
CMT1 BIT 0C7H ;P4.7 - T2 COMPARE AND TOGGLE OUTPUTS
|
||
CTI0 BIT 0C8H ;TM2IR.0 - T2 CAPTURE 0
|
||
CTI1 BIT 0C9H ;TM2IR.1 - T2 CAPTURE 1
|
||
CTI2 BIT 0CAH ;TM2IR.2 - T2 CAPTURE 2
|
||
CTI3 BIT 0CBH ;TM2IR.3 - T2 CAPTURE 3
|
||
CMI0 BIT 0CCH ;TM2IR.4 - T2 COMPARATOR 0
|
||
CMI1 BIT 0CDH ;TM2IR.5 - T2 COMPARATOR 1
|
||
CMI2 BIT 0CEH ;TM2IR.6 - T2 COMPARATOR 2
|
||
T2OV BIT 0CFH ;TM2IR.7 - T2 OVERFLOW
|
||
|
||
|
||
B-14
|
||
|
||
|
||
|
||
************************************************************************
|
||
************************************************************************
|
||
for the RUPI-44
|
||
RBP BIT 0C8H ;STS.0 - RECEIVE BUFFER PROTECT
|
||
AM BIT 0C9H ;STS.1 - AUTO/ADDRESSED MODE SELECT
|
||
OPB BIT 0CAH ;STS.2 - OPTIONAL POLL BIT
|
||
BOV BIT 0CBH ;STS.3 - RECEIVE BUFFER OVERRUN
|
||
SI BIT 0CCH ;STS.4 - SIU INTERRUPT FLAG
|
||
RTS BIT 0CDH ;STS.5 - REQUEST TO SEND
|
||
RBE BIT 0CEH ;STS.6 - RECEIVE BUFFER EMPTY
|
||
TBF BIT 0CFH ;STS.7 - TRANSMIT BUFFER FULL
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 8052/8032, 80C154/83C154, 80C51FA/83C51FA(83C252/80C252)
|
||
CAP2 BIT 0C8H ;T2CON.0 - CAPTURE OR RELOAD SELECT
|
||
CNT2 BIT 0C9H ;T2CON.1 - TIMER OR COUNTER SELECT
|
||
TR2 BIT 0CAH ;T2CON.2 - TIMER 2 ON/OFF CONTROL
|
||
EXEN2 BIT 0CBH ;T2CON.3 - TIMER 2 EXTERNAL ENABLE FLAG
|
||
TCLK BIT 0CCH ;T2CON.4 - TRANSMIT CLOCK SELECT
|
||
RCLK BIT 0CDH ;T2CON.5 - RECEIVE CLOCK SELECT
|
||
EXF2 BIT 0CEH ;T2CON.6 - EXTERNAL TRANSITION FLAG
|
||
TF2 BIT 0CFH ;T2CON.7 - TIMER 2 OVERFLOW FLAG
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 83C152/80C152
|
||
EGSRV BIT 0C8H ;IEN1.0 - GSC RECEIVE VALID
|
||
EGSRE BIT 0C9H ;IEN1.1 - GSC RECEIVE ERROR
|
||
EDMA0 BIT 0CAH ;IEN1.2 - DMA CHANNEL REQUEST 0
|
||
EGSTV BIT 0CBH ;IEN1.3 - GSC TRANSMIT VALID
|
||
EDMA1 BIT 0CCH ;IEN1.4 - DMA CHANNEL REQUEST 1
|
||
EGSTE BIT 0CDH ;IEN1.5 - GSC TRANSMIT ERROR
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80512/80532
|
||
IADC BIT 0C0H ;IRCON.0 - A/D CONVERTER INTERRUPT REQ
|
||
************************************************************************
|
||
|
||
P BIT 0D0H ;PSW.0 - ACCUMULATOR PARITY FLAG
|
||
|
||
************************************************************************
|
||
for the 83C552/80C552
|
||
F1 BIT 0D1H ;PSW.1 - FLAG 1
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80512/80532
|
||
F1 BIT 0D1H ;PSW.1 - FLAG 1
|
||
MX0 BIT 0D8H ;ADCON.0 - ANALOG INPUT CH SELECT BIT 0
|
||
MX1 BIT 0D9H ;ADCON.1 - ANALOG INPUT CH SELECT BIT 1
|
||
MX2 BIT 0DAH ;ADCON.2 - ANALOG INPUT CH SELECT BIT 2
|
||
ADM BIT 0DBH ;ADCON.3 - A/D CONVERSION MODE
|
||
BSY BIT 0DCH ;ADCON.4 - BUSY FLAG
|
||
BD BIT 0DFH ;ADCON.7 - BAUD RATE ENABLE
|
||
************************************************************************
|
||
|
||
OV BIT 0D2H ;PSW.2 - OVERFLOW FLAG
|
||
RS0 BIT 0D3H ;PSW.3 - REGISTER BANK SELECT 0
|
||
|
||
|
||
B-15
|
||
|
||
|
||
|
||
RS1 BIT 0D4H ;PSW.4 - REGISTER BANK SELECT 1
|
||
F0 BIT 0D5H ;PSW.5 - FLAG 0
|
||
AC BIT 0D6H ;PSW.6 - AUXILIARY CARRY FLAG
|
||
CY BIT 0D7H ;PSW.7 - CARRY FLAG
|
||
|
||
************************************************************************
|
||
for the 80C51FA/83C51FA(83C252/80C252)
|
||
CCF0 BIT 0D8H ;CCON.0 -PCA MODULE 0 INTERRUPT FLAG
|
||
CCF1 BIT 0D9H ;CCON.1 -PCA MODULE 1 INTERRUPT FLAG
|
||
CCF2 BIT 0DAH ;CCON.2 -PCA MODULE 2 INTERRUPT FLAG
|
||
CCF3 BIT 0DBH ;CCON.3 -PCA MODULE 3 INTERRUPT FLAG
|
||
CCF4 BIT 0DCH ;CCON.4 -PCA MODULE 4 INTERRUPT FLAG
|
||
CR BIT 0DEH ;CCON.6 - COUNTER RUN
|
||
CF BIT 0DFH ;PCA COUNTER OVERFLOW FLAG
|
||
************************************************************************
|
||
************************************************************************
|
||
for the RUPI-44
|
||
SER BIT 0D8H ;NSNR.0 - RECEIVE SEQUENCE ERROR
|
||
NR0 BIT 0D9H ;NSNR.1 - RECEIVE SEQUENCE COUNTER-BIT 0
|
||
NR1 BIT 0DAH ;NSNR.2 - RECEIVE SEQUENCE COUNTER-BIT 1
|
||
NR2 BIT 0DBH ;NSNR.3 - RECEIVE SEQUENCE COUNTER-BIT 2
|
||
SES BIT 0DCH ;NSNR.4 - SEND SEQUENCE ERROR
|
||
NS0 BIT 0DDH ;NSNR.5 - SEND SEQUENCE COUNTER-BIT 0
|
||
NS1 BIT 0DEH ;NSNR.6 - SEND SEQUENCE COUNTER-BIT 1
|
||
NS2 BIT 0DFH ;NSNR.7 - SEND SEQUENCE COUNTER-BIT 2
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80515/80535
|
||
MX0 BIT 0D8H ;ADCON.0 - ANALOG INPUT CH SELECT BIT 0
|
||
MX1 BIT 0D9H ;ADCON.1 - ANALOG INPUT CH SELECT BIT 1
|
||
MX2 BIT 0DAH ;ADCON.2 - ANALOG INPUT CH SELECT BIT 2
|
||
ADM BIT 0DBH ;ADCON.3 - A/D CONVERSION MODE
|
||
BSY BIT 0DCH ;ADCON.4 - BUSY FLAG
|
||
CLK BIT 0DEH ;ADCON.5 - SYSTEM CLOCK ENABLE
|
||
BD BIT 0DFH ;ADCON.7 - BAUD RATE ENABLE
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C652/83C652
|
||
CR0 BIT 0D8H ;S1CON.0 - CLOCK RATE 0
|
||
CR1 BIT 0D9H ;S1CON.1 - CLOCK RATE 1
|
||
AA BIT 0DAH ;S1CON.2 - ASSERT ACKNOWLEDGE
|
||
SI BIT 0DBH ;S1CON.3 - SIO1 INTERRUPT BIT
|
||
STO BIT 0DCH ;S1CON.4 - STOP FLAG
|
||
STA BIT 0DDH ;S1CON.5 - START FLAG
|
||
ENS1 BIT 0DEH ;S1CON.6 - ENABLE SIO1
|
||
************************************************************************
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
B-16
|
||
|
||
|
||
|
||
************************************************************************
|
||
for the 83C152/80C152
|
||
DMA BIT 0D8H ;TSTAT.0 - DMA SELECT
|
||
TEN BIT 0D9H ;TSTAT.1 - TRANSMIT ENABLE
|
||
TFNF BIT 0DAH ;TSTAT.2 - TRANSMIT FIFO NOT FULL
|
||
TDN BIT 0DBH ;TSTAT.3 - TRANSMIT DONE
|
||
TCDT BIT 0DCH ;TSTAT.4 - TRANSMIT COLLISION DETECT
|
||
UR BIT 0DDH ;TSTAT.5 - UNDERRUN
|
||
NOACK BIT 0DEH ;TSTAT.6 - NO ACKNOWLEDGE
|
||
LNI BIT 0DFH ;TSTAT.7 - LINE IDLE
|
||
HBAEN BIT 0E8H ;RSTAT.0 - HARDWARE BASED ACKNOWLEDGE EN
|
||
GREN BIT 0E9H ;RSTAT.1 - RECEIVER ENABLE
|
||
RFNE BIT 0EAH ;RSTAT.2 - RECEIVER FIFO NOT EMPTY
|
||
RDN BIT 0EBH ;RSTAT.3 - RECEIVER DONE
|
||
CRCE BIT 0ECH ;RSTAT.4 - CRC ERROR
|
||
AE BIT 0EDH ;RSTAT.5 - ALIGNMENT ERROR
|
||
RCABT BIT 0EEH ;RSTAT.6 - RCVR COLLISION/ABORT DETECT
|
||
OR BIT 0EFH ;RSTAT.7 - OVERRUN
|
||
PGSRV BIT 0F8H ;IPN1.0 - GSC RECEIVE VALID
|
||
PGSRE BIT 0F9H ;IPN1.1 - GSC RECEIVE ERROR
|
||
PDMA0 BIT 0FAH ;IPN1.2 - DMA CHANNEL REQUEST 0
|
||
PGSTV BIT 0FBH ;IPN1.3 - GSC TRANSMIT VALID
|
||
PDMA1 BIT 0FCH ;IPN1.4 - DMA CHANNEL REQUEST 1
|
||
PGSTE BIT 0FDH ;IPN1.5 - GSC TRANSMIT ERROR
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C452/83C452
|
||
OFRS BIT 0E8H ;SLCON.0 - OUTPUT FIFO CH REQ SERVICE
|
||
IFRS BIT 0E9H ;SLCON.1 - INPUT FIFO CH REQ SERVICE
|
||
FRZ BIT 0EBH ;SLCON.3 - ENABLE FIFO DMA FREEZE MODE
|
||
ICOI BIT 0ECH ;SLCON.4 - GEN INT WHEN IMMEDIATE COMMAN
|
||
OUT REGISTER IS AVAILABLE
|
||
ICII BIT 0EDH ;SLCON.5 - GEN INT WHEN A COMMAND IS
|
||
WRITTEN TO IMMEDIATE COMMAND IN REG
|
||
OFI BIT 0EEH ;SLCON.6 - ENABLE OUTPUT FIFO INTERRUPT
|
||
IFI BIT 0EFH ;SLCON.7 - ENABLE INPUT FIFO INTERRUPT
|
||
EFIFO BIT 0F8H ;IEP.0 - FIFO SLAVE BUS I/F INT EN
|
||
PDMA1 BIT 0F9H ;IEP.1 - DMA CHANNEL REQUEST 1
|
||
PDMA0 BIT 0FAH ;IEP.2 - DMA CHANNEL REQUEST 0
|
||
EDMA1 BIT 0FBH ;IEP.3 - DMA CHANNEL 1 INTERRUPT ENABLE
|
||
EDMA0 BIT 0FCH ;IEP.4 - DMA CHANNEL 0 INTERRUPT ENABLE
|
||
PFIFO BIT 0FDH ;IEP.5 - FIFO SLAVE BUS I/F INT PRIORITY
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C451/83C451
|
||
IBF BIT 0E8H ;CSR.0 - INPUT BUFFER FULL
|
||
OBF BIT 0E9H ;CSR.1 - OUTPUT BUFFER FULL
|
||
IDSM BIT 0EAH ;CSR.2 - INPUT DATA STROBE
|
||
OBFC BIT 0EBH ;CSR.3 - OUTPUT BUFFER FLAG CLEAR
|
||
MA0 BIT 0ECH ;CSR.4 - AFLAG MODE SELECT
|
||
MA1 BIT 0EDH ;CSR.5 - AFLAG MODE SELECT
|
||
MB0 BIT 0EEH ;CSR.6 - BFLAG MODE SELECT
|
||
MB1 BIT 0EFH ;CSR.7 - BFLAG MODE SELECT
|
||
************************************************************************
|
||
************************************************************************
|
||
|
||
|
||
B-17
|
||
|
||
|
||
|
||
for the 83C751/83C752
|
||
CTO BIT(READ) 0D8H ;I2CFG.0 - CLOCK TIMING 0
|
||
CT1 BIT(READ) 0D9H ;I2CFG.1 - CLOCK TIMING 1
|
||
T1RUN BIT(READ) 0DCH ;I2CFG.4 - START/STOP TIMER 1
|
||
MASTRQ BIT(READ) 0DEH ;I2CFG.6 - MASTER I2C
|
||
SLAVEN BIT(READ) 0DFH ;I2CFG.7 - SLAVE I2C
|
||
CT0 BIT(WRITE)0D8H ;I2CFG.0 - CLOCK TIMING 0
|
||
CT1 BIT(WRITE)0D9H ;I2CFG.1 - CLOCK TIMING 1
|
||
TIRUN BIT(WRITE)0DCH ;I2CFG.4 - START/STOP TIMER 1
|
||
CLRTI BIT(WRITE)0DDH ;I2CFG.5 - CLEAR TIMER 1 INTERRUPT FLAG
|
||
MASTRQ BIT(WRITE)0DEH ;I2CFG.6 - MASTER I2C
|
||
SLAVEN BIT(WRITE)0DFH ;I2CFG.7 - SLAVE I2C
|
||
RSTP BIT(READ) 0F8H ;I2STA.0 - XMIT STOP CONDITION
|
||
RSTR BIT(READ) 0F9H ;I2STA.1 - XMIT REPEAT STOP COND.
|
||
MAKSTP BIT(READ) 0FAH ;I2STA.2 - STOP CONDITION
|
||
MAKSTR BIT(READ) 0FBH ;I2STA.3 - START CONDITION
|
||
XACTV BIT(READ) 0FCH ;I2STA.4 - XMIT ACTIVE
|
||
XDATA BIT(READ) 0FDH ;I2STA.5 - CONTENT OF XMIT BUFFER
|
||
RIDLE BIT(READ) 0FEH ;I2STA.6 - SLAVE IDLE FLAG
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 83C552/80C552
|
||
CR0 BIT 0D8H ;S1CON.0 - CLOCK RATE 0
|
||
CR1 BIT 0D9H ;S1CON.1 - CLOCK RATE 1
|
||
AA BIT 0DAH ;S1CON.2 - ASSERT ACKNOWLEDGE
|
||
SI BIT 0DBH ;S1CON.3 - SERIAL I/O INTERRUPT
|
||
STO BIT 0DCH ;S1CON.4 - STOP FLAG
|
||
STA BIT 0DDH ;S1CON.5 - START FLAG
|
||
ENS1 BIT 0DEH ;S1CON.6 - ENABLE SERIAL I/O
|
||
ECT0 BIT 0E8H ;IEN1.0 - ENABLE T2 CAPTURE 0
|
||
ECT1 BIT 0E9H ;IEN1.1 - ENABLE T2 CAPTURE 1
|
||
ECT2 BIT 0EAH ;IEN1.2 - ENABLE T2 CAPTURE 2
|
||
ECT3 BIT 0EBH ;IEN1.3 - ENABLE T2 CAPTURE 3
|
||
ECM0 BIT 0ECH ;IEN1.4 - ENABLE T2 COMPARATOR 0
|
||
ECM1 BIT 0EDH ;IEN1.5 - ENABLE T2 COMPARATOR 1
|
||
ECM2 BIT 0EEH ;IEN1.6 - ENABLE T2 COMPARATOR 2
|
||
ET2 BIT 0EFH ;IEN1.7 - ENABLE T2 OVERFLOW
|
||
PCT0 BIT 0F8H ;IP1.0 - T2 CAPTURE REGISTER 0
|
||
PCT1 BIT 0F9H ;IP1.1 - T2 CAPTURE REGISTER 1
|
||
PCT2 BIT 0FAH ;IP1.2 - T2 CAPTURE REGISTER 2
|
||
PCT3 BIT 0FBH ;IP1.3 - T2 CAPTURE REGISTER 3
|
||
PCM0 BIT 0FCH ;IP1.4 - T2 COMPARATOR 0
|
||
PCM1 BIT 0FDH ;IP1.5 - T2 COMPARATOR 1
|
||
PCM2 BIT 0FEH ;IP1.6 - T2 COMPARATOR 2
|
||
PT2 BIT 0FFH ;IP1.7 - T2 OVERFLOW
|
||
************************************************************************
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
B-18
|
||
|
||
|
||
|
||
************************************************************************
|
||
for the 80C517/80C537
|
||
F1 BIT 0D1H ;PSW.1 - FLAG 1
|
||
MX0 BIT 0D8H ;ADCON0.0 - ANALOG INPUT CH SELECT BIT 0
|
||
MX1 BIT 0D9H ;ADCON0.1 - ANALOG INPUT CH SELECT BIT 1
|
||
MX2 BIT 0DAH ;ADCON0.2 - ANALOG INPUT CH SELECT BIT 2
|
||
ADM BIT 0DBH ;ADCON0.3 - A/D CONVERSION MODE
|
||
BSY BIT 0DCH ;ADCON0.4 - BUSY FLAG
|
||
CLK BIT 0DEH ;ADCON0.5 - SYSTEM CLOCK ENABLE
|
||
BD BIT 0DFH ;ADCON0.7 - BAUD RATE ENABLE
|
||
************************************************************************
|
||
************************************************************************
|
||
for the 80C154/83C154
|
||
ALF BIT 0F8H ;IOCON.0 - CPU POWER DOWN MODE CONTROL
|
||
P1F BIT 0F9H ;IOCON.1 - PORT 1 HIGH IMPEDANCE
|
||
P2F BIT 0FAH ;IOCON.2 - PORT 2 HIGH IMPEDANCE
|
||
P3F BIT 0FBH ;IOCON.3 - PORT 3 HIGH IMPEDANCE
|
||
IZC BIT 0FCH ;IOCON.4 - 10K TO 100 K OHM SWITCH (P1-3)
|
||
SERR BIT 0FDH ;IOCON.5 - SERIAL PORT RCV ERROR FLAG
|
||
T32 BIT 0FEH ;IOCON.6 - 32 BIT TIMER SWITCH
|
||
WDT BIT 0FFH ;IOCON.7 - WATCHDOG TIMER CONTROL
|
||
*************************************************************************
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
B-19
|
||
|
||
|
||
|
||
|
||
APPENDIX C
|
||
|
||
|
||
RESERVED SYMBOLS
|
||
|
||
|
||
|
||
The following is a list of reserved symbols used by the Cross
|
||
Assembler. These symbols cannot be redefined.
|
||
|
||
|
||
|
||
A AB ACALL ADD
|
||
ADDC AJMP AND ANL
|
||
AR0 AR1 AR2 AR3
|
||
AR4 AR5 AR6 AR7
|
||
BIT BSEG C CALL
|
||
CJNE CLR CODE CPL
|
||
CSEG DA DATA DB
|
||
DBIT DEC DIV DJNZ
|
||
DPTR DS DSEG DW
|
||
END EQ EQU GE
|
||
GT HIGH IDATA INC
|
||
ISEG JB JBC JC
|
||
JMP JNB JNC JNZ
|
||
JZ LCALL LE LJMP
|
||
LOW LT MOD MOV
|
||
MOVC MOVX MUL NE
|
||
NOP NOT OR ORG
|
||
ORL PC POP PUSH
|
||
R0 R1 R2 R3
|
||
R4 R5 R6 R7
|
||
RET RETI RL RLC
|
||
RR RRC SET SETB
|
||
SHL SHR SJMP SUBB
|
||
SWAP USING XCH XCHD
|
||
XDATA XOR XRL XSEG
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
C-1
|
||
|
||
|
||
|
||
|
||
|
||
|
||
APPENDIX D
|
||
|
||
|
||
CROSS ASSEMBLER CHARACTER SET
|
||
---------------------------+----------------+-------------------
|
||
| PRINTABLE | ASCII CODE
|
||
CHARACTER NAME | FORM | HEX | DECIMAL
|
||
---------------------------+----------------+---------+----------
|
||
Horizontal Tab | | 09 | 9
|
||
Line Feed | | 0A | 10
|
||
Carriage Return | | 0D | 13
|
||
Space | | 20 | 32
|
||
Exclamation Point | ! | 21 | 33
|
||
Pound Sign | # | 23 | 35
|
||
Dollar Sign | $ | 24 | 36
|
||
Percent Sign | % | 25 | 37
|
||
Ampersand | & | 26 | 38
|
||
Apostrophe | ' | 27 | 39
|
||
Left Parenthesis | ( | 28 | 40
|
||
Right Parenthesis | ) | 29 | 41
|
||
Asterisk | * | 2A | 42
|
||
Plus sign | + | 2B | 43
|
||
Comma | , | 2C | 44
|
||
Hyphen | - | 2D | 45
|
||
Period | . | 2E | 46
|
||
Slash | / | 2F | 47
|
||
Number 0 | 0 | 30 | 48
|
||
" 1 | 1 | 31 | 49
|
||
" 2 | 2 | 32 | 50
|
||
" 3 | 3 | 33 | 51
|
||
" 4 | 4 | 34 | 52
|
||
" 5 | 5 | 35 | 53
|
||
" 6 | 6 | 36 | 54
|
||
" 7 | 7 | 37 | 55
|
||
" 8 | 8 | 38 | 56
|
||
" 9 | 9 | 39 | 57
|
||
Colon | : | 3A | 58
|
||
Semi-colon | ; | 3B | 59
|
||
Left Angle Bracket | < | 3C | 60
|
||
Equal Sign | = | 3D | 61
|
||
Right Angle Bracket | > | 3E | 62
|
||
Question Mark | ? | 3F | 63
|
||
At Sign | @ | 40 | 64
|
||
Upper Case A | A | 41 | 65
|
||
" " B | B | 42 | 66
|
||
" " C | C | 43 | 67
|
||
" " D | D | 44 | 68
|
||
" " E | E | 45 | 69
|
||
" " F | F | 46 | 70
|
||
" " G | G | 47 | 71
|
||
" " H | H | 48 | 72
|
||
|
||
|
||
|
||
|
||
D-1
|
||
|
||
|
||
|
||
|
||
---------------------------+----------------+-------------------
|
||
| PRINTABLE | ASCII CODE
|
||
CHARACTER NAME | FORM | HEX | DECIMAL
|
||
---------------------------+----------------+---------+----------
|
||
Upper Case I | I | 49 | 73
|
||
" " J | J | 4A | 74
|
||
" " K | K | 4B | 75
|
||
" " L | L | 4C | 76
|
||
" " M | M | 4D | 77
|
||
" " N | N | 4E | 78
|
||
" " O | O | 4F | 79
|
||
" " P | P | 50 | 80
|
||
" " Q | Q | 51 | 81
|
||
" " R | R | 52 | 82
|
||
" " S | S | 53 | 83
|
||
" " T | T | 54 | 84
|
||
" " U | U | 55 | 85
|
||
" " V | V | 56 | 86
|
||
" " W | W | 57 | 87
|
||
" " X | X | 58 | 88
|
||
" " Y | Y | 59 | 89
|
||
" " Z | Z | 5A | 90
|
||
Underscore | _ | 5F | 95
|
||
Lower Case A | a | 61 | 97
|
||
" " B | b | 62 | 98
|
||
" " C | c | 63 | 99
|
||
" " D | d | 64 | 100
|
||
" " E | e | 65 | 101
|
||
" " F | f | 66 | 102
|
||
" " G | g | 67 | 103
|
||
" " H | h | 68 | 104
|
||
" " I | i | 69 | 105
|
||
" " J | j | 6A | 106
|
||
" " K | k | 6B | 107
|
||
" " L | l | 6C | 108
|
||
" " M | m | 6D | 109
|
||
" " N | n | 6E | 110
|
||
" " O | o | 6F | 111
|
||
" " P | p | 70 | 112
|
||
" " Q | q | 71 | 113
|
||
" " R | r | 72 | 114
|
||
" " S | s | 73 | 115
|
||
" " T | t | 74 | 116
|
||
" " U | u | 75 | 117
|
||
" " V | v | 76 | 118
|
||
" " W | w | 77 | 119
|
||
" " X | x | 78 | 120
|
||
" " Y | y | 79 | 121
|
||
" " Z | z | 7A | 122
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
D-2
|
||
|
||
|
||
|
||
|
||
INDEX
|
||
|
||
A
|
||
ASCII Literals, 2-6
|
||
Assembler
|
||
Comments, 2-6
|
||
Control Description ($), 6-1
|
||
Controls, 2-3
|
||
Directives, 2-3
|
||
Error codes/messages, 8-1
|
||
Labels, 2-2
|
||
Location Counter, 2-7
|
||
Numbers, 2-7
|
||
Operators, 2-7
|
||
Running it, 3-1
|
||
Symbols, 2-1
|
||
Syntax Summary, 2-7
|
||
|
||
B
|
||
Bit Addressing, 2-6
|
||
|
||
C
|
||
Character Set, D-1
|
||
Comments, 2-6
|
||
Control Description ($)
|
||
DATE, 6-1
|
||
DEBUG, 6-2
|
||
EJECT, 6-2
|
||
INCLUDE, 6-2
|
||
LIST, 6-3
|
||
MOD152, 6-3
|
||
MOD154, 6-3
|
||
MOD252, 6-3
|
||
MOD44, 6-3
|
||
MOD451, 6-3
|
||
MOD452, 6-3
|
||
MOD51, 6-3
|
||
MOD512, 6-3
|
||
MOD515, 6-3
|
||
MOD517, 6-3
|
||
MOD52, 6-3
|
||
MOD521, 6-3
|
||
MOD552, 6-3
|
||
MOD652, 6-3
|
||
MOD751, 6-3
|
||
MOD752, 6-3
|
||
MOD851, 6-3
|
||
NODEBUG, 6-2
|
||
NOLIST, 6-3
|
||
NOMOD, 6-3
|
||
NOOBJECT, 6-5
|
||
NOPAGING, 6-5
|
||
NOPRINT, 6-6
|
||
NOSYMBOLS, 6-6
|
||
OBJECT, 6-5
|
||
|
||
|
||
1
|
||
|
||
|
||
|
||
|
||
PAGELENGTH, 6-5
|
||
PAGEWIDTH, 6-6
|
||
PAGING, 6-5
|
||
PRINT, 6-6
|
||
SYMBOLS, 6-6
|
||
TITLE, 6-7
|
||
Controls
|
||
Description, 6-1
|
||
Introduction, 2-3, 6-1
|
||
|
||
D
|
||
Directive
|
||
Assembler, 2-3
|
||
Conditional Assembly, 5-8
|
||
Introduction, 5-1
|
||
Memory Reservation, 5-5
|
||
Miscellaneous, 5-7
|
||
Segment Selection, 5-4
|
||
Storage, 5-5
|
||
Symbol, 5-1
|
||
Directives
|
||
BIT, 5-2
|
||
BSEG, 5-4
|
||
CODE, 5-2
|
||
CSEG, 5-4
|
||
DATA, 5-3
|
||
DB, 5-5
|
||
DBIT, 5-5
|
||
DS, 5-5
|
||
DSEG, 5-4
|
||
DW, 5-6
|
||
ELSE, 5-8
|
||
END, 5-8
|
||
ENDIF, 5-8
|
||
EQU, 5-1
|
||
IDATA, 5-3
|
||
IF, 5-8
|
||
ISEG, 5-4
|
||
ORG, 5-7
|
||
SET, 5-1
|
||
XDATA, 5-3
|
||
XSEG, 5-4
|
||
|
||
E
|
||
Error Codes
|
||
Explainations, 8-2
|
||
Introduction, 8-1
|
||
Numerical Listing, 8-2
|
||
Executing
|
||
Assembler, 3-1
|
||
Assembler Example, 3-3
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
2
|
||
|
||
|
||
|
||
|
||
F
|
||
File
|
||
ASM51 Cross Assembler Diskette, 3-1
|
||
Object, 2-11
|
||
Source Listing, 2-10
|
||
Source Listing Sample, A-4
|
||
|
||
H
|
||
Hardware
|
||
Requirements, 3-1
|
||
|
||
I
|
||
Instruction
|
||
BYT, 4-3
|
||
CYC, 4-3
|
||
Dest/Source ADDR Mode, 4-2
|
||
HEX Opcode, 4-3
|
||
Language Form, 4-2
|
||
Mnemonics, 2-4, 4-1
|
||
Notation, 4-1
|
||
Operation, 4-1
|
||
PSW, 4-3
|
||
Set, 4-4
|
||
Introduction
|
||
Controls, 6-1
|
||
Cross Assembler, 2-1
|
||
Directives, 5-1
|
||
Error codes/messages, 8-1
|
||
Macro Processor, 7-1
|
||
|
||
L
|
||
Labels, 2-2
|
||
Location Counter, 2-7
|
||
|
||
M
|
||
Macro
|
||
Definition, 7-1
|
||
Special Operators, 7-4
|
||
Using, Labels, 7-6
|
||
Using, Nesting, 7-4
|
||
Using them, 7-4
|
||
Macro Processor
|
||
Introduction, 7-1
|
||
Microcontroller
|
||
Architecture MCS-51, 1-2
|
||
Background MCS-51, 1-1
|
||
Supported, 1-4
|
||
Mnemonics
|
||
MCS-51, 2-4
|
||
Notations, 4-1
|
||
Summary, 4-4
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
3
|
||
|
||
|
||
|
||
|
||
N
|
||
Numbers, 2-7
|
||
|
||
O
|
||
Operators, 2-7
|
||
Overview
|
||
Cross Assembler, 2-1
|
||
Symbols, 2-1
|
||
|
||
P
|
||
Program Sample, A-1
|
||
|
||
R
|
||
Reserved Symbols, 2-2
|
||
|
||
S
|
||
Sample program, A-1
|
||
Symbols
|
||
Directive Definition, 5-1
|
||
Labels, 2-2
|
||
Overview, 2-1
|
||
Reserved, 2-2
|
||
Reserved list, C-1
|
||
Syntax Summary, 2-7
|
||
System
|
||
DOS hints, 3-3
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
|
||
4
|